Hemodynamic investigation of hemorrhagic stroke treatment options for a patient-specific aneurysm using a porous medium model

Author:

Panneerselvam Nisanth Kumar1ORCID,Akade Bhushan2ORCID,Kumar Adarsh Anil3ORCID,Sudhir B. J.12ORCID,Kannath Santhosh K.3ORCID,Patnaik B. S. V.1ORCID

Affiliation:

1. Department of Applied Mechanics and Biomedical Engineering, Indian Institute of Technology Madras 1 , Chennai 600036, India

2. Department of Neurosurgery, Sree Chitra Tirunal Institute for Medical Sciences and Technology 2 , Thiruvananthapuram 695011, India

3. Department of Imaging Sciences and Interventional Radiology, Sree Chitra Tirunal Institute for Medical Sciences and Technology 3 , Thiruvananthapuram 695011, India

Abstract

A ruptured intracranial aneurysm is a serious life-threatening medical condition. Bleed in the cerebral circulation causes subarachnoid hemorrhage, which is known as hemorrhagic stroke. The present study investigates cerebral blood circulation and aneurysm bleed using the principle of fluid mechanics. Ruptured wide-neck aneurysms are difficult to treat either by surgical clipping or stent-assisted coiling in the acute phase of rupture. Quick and intentional partial coiling (IPC) around the aneurysm rupture region is preferred for an immediate cessation of rebleed after rupture. Furthermore, the stent-assisted complete coiling (SACC) may be performed once the patient is stable and able to withstand the antiplatelet therapy at a later stage. The aneurysm recurrence and rupture after the treatment are the major issues associated with the treatment of a wide-necked aneurysm. The present study analyzes the hemodynamics of IPC followed by SACC using a novel multi-domain porous medium approach. Simulations are performed assuming a hypothesized rupture spot for the aneurysm using flow features and hemodynamic parameters. The optimal coil packing density (PD) required to fill the vicinity of the ruptured spot to prevent early rebleed and facilitate aneurysm occlusion is numerically determined. It is observed that partial coiling requires higher packing density (PD > 30%) than complete coiling to reduce the chances of aneurysm recurrence after the treatment. The insertion of the stent does not affect the aneurysm hemodynamics significantly. The stent-assisted complete coiling requires more than 20% PD to enhance the long-term stability of the treatment.

Publisher

AIP Publishing

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3