Absolute response of a proton detector composed of a microchannel plate assembly and a charge-coupled device to laser-accelerated multi-MeV protons

Author:

Mahmood M. Ahsan123ORCID,Ahn Gwang-Eun1ORCID,Lee Sang Hwa1,Kim Seung Yeon1,Ahmad Izhar3,Tahir Sajjad2,Yang Jeong Moon1ORCID,Yoon Jin Woo14ORCID,Sung Jae Hee14ORCID,Lee Seong Ku14ORCID,Choi Il Woo14ORCID,Nam Chang Hee15ORCID

Affiliation:

1. Center for Relativistic Laser Science, Institute for Basic Science, Gwangju Institute of Science and Technology, Gwangju 61005, Republic of Korea

2. Department of Physics and Applied Mathematics, Pakistan Institute of Engineering and Applied Sciences, Islamabad 45650, Pakistan

3. National Institute of Lasers and Optronics College, Pakistan Institute of Engineering and Applied Sciences, Islamabad 45650, Pakistan

4. Advanced Photonics Research Institute, Gwangju Institute of Science and Technology, Gwangju 61005, Republic of Korea

5. Department of Physics and Photon Science, Gwangju Institute of Science and Technology, Gwangju 61005, Republic of Korea

Abstract

The absolute response of a real-time proton detector, composed of a microchannel plate (MCP) assembly, an imaging lens, and a charge-coupled device (CCD) camera, is calibrated for the spectral characterization of laser-accelerated protons, using a Thomson parabola spectrometer (TPS). A slotted CR-39 plate was used as an absolute particle-counting detector in the TPS, simultaneously with the MCP–CCD detector to obtain a calibration factor (count/proton). In order to obtain the calibration factor as a function of proton energy for a wide range of proton numbers, the absolute response was investigated for different operation parameters of the MCP–CCD detector, such as MCP voltage, phosphor voltage, and CCD gain. A theoretical calculation for the net response of the MCP was in good agreement with the calibrated response of the MCP–CCD detector, and allows us to extend the response to higher proton energies. The response varies in two orders of magnitude, showing an exponential increase with the MCP voltage and almost linear increase with the phosphor voltage and the CCD gain. The calibrated detector enabled characterization of a proton energy spectrum in a wide dynamic range of proton numbers. Moreover, two MCP assemblies having different structures of MCP, phosphor screen, and optical output window have been calibrated, and the difference in the absolute response was highlighted. The highly-sensitive detector operated with maximum values of the parameters enables measuring a single proton particle and evaluating an absolute spectrum at high proton energies in a single laser shot. The absolute calibrations can be applied for the spectral measurement of protons using different operating voltages and gains for optimized response in a large range of proton energy and number.

Funder

Institute for Basic Science

Gwangju Institute of Science and Technology

Publisher

AIP Publishing

Subject

Instrumentation

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3