Affiliation:
1. State Key Laboratory of Electrical Insulation and Power Equipment, Xi’an Jiaotong University 1 , Xi’an 710049, China
2. State Key Laboratory of Intense Pulsed Radiation Simulation and Effect, Northwest Institute of Nuclear Technology 2 , Xi’an 710024, China
Abstract
Large-scale linear transformer drivers (LTDs) are composed of numerous high-power gas switches, and switch prefire is a frequent operational fault. To detect and locate the faulty switch accurately and efficiently, a two-terminal location method is proposed. A B-dot sensor is integrated on the gas switch’s shell to collect the discharging signal. All the B-dot sensors are connected in parallel through cables of equal length. The fault position can be determined by the time delay of the signals at the two terminals. A diode is inserted between the B-dot sensor’s coil and the cable core to ensure low-loss transmission of the signal. Two methods are applied in fault location, including time-of-arrival (TOA) and time reversal (TR). For the TOA method, an energy criterion and a phase criterion are applied and compared. The accuracy of the energy criterion is greatly influenced by the signal-to-noise ratio, while the phase criterion requires a reasonable estimate of the actual delay to account for the impact of phase periodicity. The TR method based on a precise simulation model is established, which demonstrates high precision in location. The TR method has been tested and validated on a single stage LTD module. Moreover, the location method for double switches prefire is discussed theoretically. The method proposed in this paper will be helpful to improve the efficiency of the commissioning, operation, and maintenance of the large-scale LTD devices.
Funder
National Natural Science Foundation of China