Application of high precision wavelength calibration method for plasmas rotation measurement based on Fabry–Pérot etalon on experimental advanced superconducting tokamak

Author:

Fu Shengyu12ORCID,Yin Xianghui1ORCID,Fu Jia2ORCID,Li Yingying3ORCID,Wang Fudi2ORCID,Zhang Hongming2ORCID,Bae Cheonho2,Lyu Bo2ORCID,Huang Qianhong1ORCID,Shen Yongcai45,Li Yichao2,He Liang2,Jin Yifei2,Gong Xueyu1ORCID

Affiliation:

1. School of Nuclear Science and Technology, University of South China, Hengyang, Hunan 421001, China

2. Institute of Plasma Physics, Chinese Academy of Sciences, Hefei, Anhui 230031, China

3. Hebei Key Laboratory of Compact Fusion, Langfang, Hebei 065001, China

4. School of Physics and Materials Engineering, Hefei Normal University, Hefei, Anhui 230601, China

5. Institute of Energy, Hefei Comprehensive National Science Center, Hefei, Anhui 230031, China

Abstract

Analyzing the radiation spectra of impurity ions is a widely applied diagnostic scheme for plasma ion temperature and rotation measurements on tokamaks. High precision wavelength calibration is a prerequisite for the accurate measurement of plasma parameters, especially for plasma rotation. Furthermore, the sparseness or absence of the standard spectral lines brings calibration challenges due to the narrow wavelength range. A precise wavelength calibration method is demonstrated in which the comb-like spectra generated by the Fabry–Pérot etalon can lock a series of fixed peaks as reference points in a wide wavelength range. The equal frequency intervals of the comb-like spectra are further corrected using several characteristic neon lines of known wavelengths. The experimental results indicate that the wavelength accuracy obtained by this calibration method is less than 0.005 nm, which corresponds to a rotation speed of 2.3 km/s in the toroidal direction for the beam emission spectroscopy spectrometer installed on the experimental advanced superconducting tokamak. Taking the O V(650.024 nm, n = 4 → 3) line as an example, the maximum difference in the oxygen ion rotation velocity is 3.8 km/s for the absolute rotation of ∼25 km/s, when compared with the calibration results of a standard lamp.

Funder

National Magnetic Confinement Fusion Program of China

National Natural Science Foundation of China

Collaborative Innovation Program of Hefei Science Center, CAS

Natural Science Foundation of Anhui Province

Comprehensive Research Facility for Fusion Technology Program of China

Natural Science Foundation of Hunan Province

The CAS President’s International Fellowship Initiative

Publisher

AIP Publishing

Subject

Instrumentation

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3