Analysis and fabrication of a small-scale radio-frequency balun for magnetic resonance imaging amplifier

Author:

Li Yingliang1ORCID,Luo Shouhua1,Liu Chunyi2,Ye Yuanyuan3

Affiliation:

1. School of Biological Science and Medical Engineering, Southeast University, Nanjing, China

2. Center for Molecular Imaging and Nuclear Medicine, State Key Laboratory of Radiation Medicine and Protection, School for Radiological and Interdisciplinary Sciences (RAD-X), Soochow University, Suzhou, China

3. Xingaoyi Medical Equipment Co., Ltd., No. 555, Yeshan Road, Yuyao, Zhejiang, China

Abstract

In this study, the authors report the design and fabrication of a small mixed-integrated balun for magnetic resonance imaging (MRI). The device was designed by using the positive anti-symmetric coupling method, which applies the lump surface-mount technology capacitors as well as mirror-symmetric coupling strips that were etched on the top and bottom layers of a printed circuit board. The capacitors reduced the length of the coupling strips and compensated for imbalances in the phase and gain due to errors in the fabrication process. The structure and equivalent even–odd circuit model of the device was modeled and examined using commercial software to optimize the design parameters. Following this, the device was fabricated and its performance was assessed through measurements using a network analyzer. The results showed that imbalances in the gain and phase were lower than 0.1 dB and 1°, respectively, and the insertion loss and the input voltage standing-wave ratio (VSWR) were lower than 0.4 dB and −25 dB, respectively. More importantly, the device was small, with dimensions of 50 × 60 × 1.5 mm. This makes it suitable for MRI applications involving highly integrated miniaturized systems. The proposed device was integrated into a 3.0 T radio-frequency power amplifier (RFPA) and reduced the dimensions of its power modules by 20% compared with the traditional balun. Finally, the RFPA module was used in an 3.0T MRI system for imaging experiments, and the results showed that the balun can help obtain high-quality scanning images.

Funder

Ministry of Science and Technology of China

3.0T MRI System of XGY Company of China

Publisher

AIP Publishing

Subject

Instrumentation

Reference17 articles.

1. Q. Sun, J. Yuan, V. T. Vo, and A. A. Rezazadeh, Proceeding of the 36th EuMC (IEEE, 2006), pp. 68–71.

2. A Coupler-Based Differential mm-Wave Doherty Power Amplifier With Impedance Inverting and Scaling Baluns

3. Y. C. Leong, K. S. Ang, and C. H. Lee, IEEE MTT-S Digest (IEEE, 2002), pp. 1165–1168.

4. C.W. Tang and C.Y. Chang, IEEE MTT-S Digest (IEEE, 2002), pp. 2201–2204.

5. Modified Wideband Marchand Balun With Tunable Power Division Ratio and Constant Phase

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Design and Realization of Time-domain Transfer DPD Method for MRI RF Power Amplifiers;2023 6th International Conference on Electronics Technology (ICET);2023-05-12

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3