Affiliation:
1. College of Advanced Interdisciplinary Studies, National University of Defense Technology, Changsha 410073, China
2. State Key Laboratory of Pulsed Power Laser Technology, Hefei 230037, China
Abstract
In this paper, a transmission line with five spiral-wires in parallel was designed. The transit time and the characteristic impedance of the transmission line are 200 ns and 14 Ω, respectively. Its slow wave coefficient is close to 13. The insulating medium of the transmission line is glycerin. In order to investigate the breakdown strength of glycerin under a hundred-nanosecond pulse, simulations and experiments are conducted. The results indicate that the breakdown strength of glycerin under hundred nanoseconds reached 653 kV/cm, which is a 400 kV/cm increase compared with that under a microsecond pulse. However, under hundred nanoseconds, the breakdown strength of glycerin in transmission is unaffected by pressure within 1 MPa, and pressure is conducive to the insulation recovery of glycerin.
Subject
General Physics and Astronomy