GermanIum array for non-destructive testing (GIANT) setup for muon-induced x-ray emission (MIXE) at the Paul Scherrer Institute

Author:

Gerchow Lars1ORCID,Biswas Sayani1ORCID,Janka Gianluca1ORCID,Vigo Carlos1ORCID,Knecht Andreas2ORCID,Vogiatzi Stergiani Marina2ORCID,Ritjoho Narongrit3ORCID,Prokscha Thomas1ORCID,Luetkens Hubertus1ORCID,Amato Alex1ORCID

Affiliation:

1. Laboratory of Muon Spin Spectroscopy, Neutron and Muon Division, Paul Scherrer Institute 1 , Forschungsstrasse 111, 5232 PSI-Villigen, Switzerland

2. Laboratory of Particle Physics, Neutron and Muon Division, Paul Scherrer Institute 2 , Forschungsstrasse 111, 5232 PSI-Villigen, Switzerland

3. School of Physics, Institute of Science, Suranaree University of Technology 3 , 111 University Avenue Muang, Nakhon Ratchasima 30000, Thailand

Abstract

The usage of muonic x-rays to study elemental properties like nuclear radii ranges back to the seventies. This triggered the pioneering work at the Paul Scherrer Institute (PSI), during the eighties on the Muon-induced x-ray emission (MIXE) technique for a non-destructive assessment of elemental compositions. In recent years, this method has seen a rebirth, improvement, and adoption at most muon facilities around the world. Hereby, the PSI offers unique capabilities with its high-rate continuous muon beam at the Swiss Muon Source (SμS). We report here the decision-making, construction, and commissioning of a dedicated MIXE spectrometer at PSI, the GermanIum Array for Non-destructive Testing (GIANT) setup. Multiple campaigns highlighted the outstanding capabilities of MIXE at PSI, e.g., resolving down to 1 at. % elemental concentrations with as little as 1 h data taking, measuring isotopic ratios for elements from iron to lead, and characterizing gamma rays induced by muon nuclear capture. On-target beam spots were characterized with a dedicated charged particle tracker to be symmetric to 5% with an average σ = 22.80(25) and 14.41(8) mm for 25 and 45 MeV/c, respectively. Advanced analysis of the high-purity germanium signals further allows us to improve energy and timing resolutions to ∼1 keV and 20 ns at 1 MeV, respectively. Within the GIANT setup, an average detector has a photopeak efficiency of ϵĒ=0.11% and an energy resolution of σĒ=0.8keV at E = 1000 keV. The overall performance of the GIANT setup at SμS allowed us to start a rich user program with archaeological samples, Li-ion battery research, and collaboration with the industry. Future improvements will include a simulation-based analysis and a higher degree of automation, e.g., automatic scans of a series of muon momenta and automatic sample changing.

Funder

Schweizerischer Nationalfonds zur Förderung der Wissenschaftlichen Forschung

Publisher

AIP Publishing

Subject

Instrumentation

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Development of wide range photon detection system for muonic X-ray spectroscopy;Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment;2024-03

2. An arrowhead made of meteoritic iron from the late Bronze Age settlement of Mörigen, Switzerland and its possible source;Journal of Archaeological Science;2023-09

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3