Simulation of atrial fibrillation in a non-ohmic propagation model with dynamic gap junctions

Author:

Saliani Ariane12,Biswas Subhamoy12ORCID,Jacquemet Vincent12ORCID

Affiliation:

1. Institute of Biomedical Engineering, Department of Pharmacology and Physiology, Faculty of Medicine, Université de Montréal, C.P. 6128, succ. Centre-ville, Montreal, Quebec H3C 3J7, Canada

2. Research Center, Hôpital du Sacré-Coeur, CIUSSS du Nord-de-l’Île-de-Montréal, 5400 boul. Gouin Ouest, Montreal, Quebec H4J 1C5, Canada

Abstract

Gap junctions exhibit nonlinear electrical properties that have been hypothesized to be relevant to arrhythmogenicity in a structurally remodeled tissue. Large-scale implementation of gap junction dynamics in 3D propagation models remains challenging. We aim to quantify the impact of nonlinear diffusion during episodes of arrhythmias simulated in a left atrial model. Homogenization of conduction properties in the presence of nonlinear gap junctions was performed by generalizing a previously developed mathematical framework. A monodomain model was solved in which conductivities were time-varying and depended on transjunctional potentials. Gap junction conductances were derived from a simplified Vogel–Weingart model with first-order gating and adjustable time constant. A bilayer interconnected cable model of the left atrium with 100 [Formula: see text]m resolution was used. The diffusion matrix was recomputed at each time step according to the state of the gap junctions. Sinus rhythm and atrial fibrillation episodes were simulated in remodeled tissue substrates. Slow conduction was induced by reduced coupling and by diffuse or stringy fibrosis. Simulations starting from the same initial conditions were repeated with linear and nonlinear gap junctions. The discrepancy in activation times between the linear and nonlinear diffusion models was quantified. The results largely validated the linear approximation for conduction velocities >20 cm/s. In very slow conduction substrates, the discrepancy accumulated over time during atrial fibrillation, eventually leading to qualitative differences in propagation patterns, while keeping the descriptive statistics, such as cycle lengths, unchanged. The discrepancy growth rate was increased by impaired conduction, fibrosis, conduction heterogeneity, lateral uncoupling, fast gap junction time constant, and steeper action potential duration restitution.

Funder

Natural Sciences and Engineering Research Council of Canada

Publisher

AIP Publishing

Subject

Applied Mathematics,General Physics and Astronomy,Mathematical Physics,Statistical and Nonlinear Physics

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3