Unlocking a lower shot noise limit in dual-comb interferometry

Author:

Walsh M.1ORCID,Guay P.1ORCID,Genest J.1ORCID

Affiliation:

1. Centre d’optique, photonique et laser, Université Laval , Québec, Québec G1V 0A6, Canada

Abstract

Optimizing the signal-to-noise ratio (SNR) is critical to achieve high sensitivities across broad spectral ranges in dual-comb interferometry. Sensitivity can be improved through time-averaging, but only at the cost of reduced temporal resolution. We show that it is instead possible to use high-bandwidth detection combined with frequency-domain averaging of multiple copies of the dual-comb beat note. By controlling the signal and noise stationarity properties, one can even reduce the fundamental shot noise contribution compared to the normal, single copy, dual-comb operation where integration time is matched to, or larger than the repetition period. In principle, the use of Na aliased frequency-domain copies will improve SNR by up to Na, or equivalently, reduce acquisition time by a factor of Na. We demonstrate dual-comb interferometry using Na = 5 aliases, achieving the predicted fivefold reduction in shot noise power density at low frequencies. Over the full spectrum, unaveraged relative intensity noise limits the SNR, but we measure a 1.65× fold improvement in detection of CO2, corresponding to a 2.7× reduction in acquisition time for a given precision.

Funder

Natural Sciences and Engineering Research Council of Canada

Publisher

AIP Publishing

Subject

Computer Networks and Communications,Atomic and Molecular Physics, and Optics

Reference28 articles.

1. Dual-comb spectroscopy;Optica,2016

2. The time-programmable frequency comb and its use in quantum-limited ranging;Nature,2022

3. Dual-comb electric-field cross-correlation technique for optical arbitrary waveform characterization;Opt. Lett.,2009

4. Advanced ultrafast technologies based on optical frequency combs;IEEE J. Sel. Top. Quantum Electron.,2012

5. Simultaneous and self-referenced amplitude and phase measurement of two frequency combs using multi-heterodyne spectroscopy,2012

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

1. Reconsidering shot noise in dual-comb spectroscopy;Optica Sensing Congress 2023 (AIS, FTS, HISE, Sensors, ES);2023

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3