Effects of Duct Height and Fire Location on Fire Phenomena of Enclosure with Two Horizontal Vents Installed on Ceiling

Author:

Park Yu Mi,Lee Chi Young

Abstract

The effects of duct height (DH) and fire location (FL) in an enclosure on the mass flow rate and flow pattern of horizontal vent (HV) flow and temperature distribution in the enclosure were investigated through numerical simulations under the condition that two HVs were installed on the ceiling of the enclosure. To evaluate the effect of DH, DHs of HV1 were set to 0.19 m (HV1_DH0.19) and 0.05 m (HV1_DH0.05) under the condition that DH of HV2 was 0.05 m (HV2_DH0.05). The effect of FL was evaluated in three cases where the fire sources were located in the center of the floor (F LC), below HV1 (F L1), and below HV2 (F L2). With respect to the DH effect, the total mass flow rate of the vent flow was slightly higher and temperature was slightly lower in the case of HV1_DH0.19 than that in the case of HV1_DH0.05. However, considering the error bars, the effect of DH in this numerical simulation condition was considered to be insignificant. Furthermore, bidirectional flow patterns appeared in HV1 and HV2 in both DH conditions. Meanwhile, with respect to the FL effect, a bidirectional flow dominated by the mass flow rate of outflow occurred in the HV where the fire source was located, and a unidirectional inflow dominated by the mass flow rate of inflow occurred in the HV where the fire source was not located. The total mass flow rates of FL1 and FL2 conditions were similar, which were higher than those of FLC condition. The temperature was higher in FLC than those in FL1 and FL2. This was due to the small mass flow rate through the HV in the FLC. Meanwhile, an increasing trend of the temperature with the rising measurement height from the floor was observed at most of the temperature measurement points. However, when the fire source was located below HV1 and HV2, as the height from the floor increased, the temperature decreased and the overall temperature was low at the temperature measurement points below the vent where the fire source was not located. This trend was attributed to the occurrence of a strong unidirectional inflow wherein a large volume of low-temperature air flowed into the enclosure from the HV where the fire source was not located.

Funder

National Research Foundation of Korea

Ministry of Science and ICT

National Fire Agency

Publisher

Korea Institute of Fire Science and Engineering

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3