Use of an automated knot fastener shortens operative times in minimally invasive mitral valve repair

Author:

Perin G1,Shaw M1,Pingle V1,Palmer K1,Al-Rawi O1,Ridgway T1,Pousios D1,Modi P1

Affiliation:

1. Liverpool Heart and Chest Hospital NHS Foundation Trust, Liverpool, UK

Abstract

Introduction Longer durations of cardiopulmonary bypass and aortic cross clamp are associated with increased morbidity and mortality. Little is known about the effect of automated knot fasteners (Cor-Knot®) in minimally invasive mitral valve repair on operative times and outcomes. The aim of this study was to evaluate whether these devices shortened cardiopulmonary bypass and aortic cross clamp times and whether this impacted on postoperative outcomes. Materials and methods All patients undergoing isolated minimally invasive mitral valve repair by a single surgeon between March 2011 and March 2016 were included (n = 108). Two cohorts were created based on the use (n = 52) or non-use (n = 56) of an automated knot fastener. Data concerning intraoperative variables and postoperative outcomes were collected and compared. Results Preoperative demographics were well matched between groups with no significant difference in logistic Euroscore (manual vs automated: median 3.1, interquartile range, IQR, 2.1–5.5, vs 5.4, IQR 2.2–8.3; P = 0.07, respectively). Comparing manually tied knots to an automated fastener, cardiopulmonary bypass and aortic cross clamp times were significantly shorter in the automated group (cardiopulmonary bypass: median 200 minutes, IQR 180–227, vs 165 minutes (IQR 145–189 minutes), P < 0.001; aortic cross clamp 134 minutes (IQR 121–150 minutes) vs 111 minutes (IQR 91–137 minutes), P < 0.001, respectively). There was no mortality and no strokes, nor were there any differences in postoperative outcomes including reoperation for bleeding, renal failure, intensive care or hospital stay. Conclusions The use of an automated knot fastener significantly reduces cardiopulmonary bypass and aortic cross clamp times in minimally invasive mitral valve repair but this does not translate into an improved clinical outcome.

Publisher

Royal College of Surgeons of England

Subject

General Medicine,Surgery

Cited by 9 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3