Affiliation:
1. Kingston Hospital NHS Trust, UK
Abstract
We describe explosive combustion of a gas filled peritoneum from a handheld electrosurgery electrode used to enter the abdomen. The pneumoperitoneum was due to small bowel perforation and peritonitis had been established for at least two days. No injury was caused to either the patient or medical staff. This rare occurrence has only been described once before. Surgeons should be aware of the possible combustion of bowel gas, whether on opening bowel or the peritoneum after bowel perforation.
Publisher
Royal College of Surgeons of England
Cited by
4 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献