Affiliation:
1. North West London Hospitals NHS Trust,UK
Abstract
INTRODUCTION Floseal® (Baxter, Hayward, CA, US) can be of value in reducing blood loss and haematoma rates. The manufacturer’s warnings include allergic reaction, poor wound healing and intravascular thrombosis. We aimed to determine whether Floseal® is safe to use in various head and neck surgery (HNS) procedures. METHODS A prospective trial was conducted using Floseal® in 42 various consecutive head and neck surgery procedures. Adverse incidents were used as the main outcome measure, including allergic reaction, wound breakdown, wound infection and thrombosis. Secondary outcome measures included haematoma formation, hospital stay, drain times and output. RESULTS No adverse incidents were recorded in the trial period. Two patients developed haematomas and required surgical exploration where a bleeding vessel was identified and dealt with. CONCLUSIONS Floseal® is safe to be used in head and neck surgery with no adverse effects. A larger number and a control group are required to ascertain its value in reducing blood loss, haematoma formation, drain usage and hospital stay.
Publisher
Royal College of Surgeons of England
Cited by
31 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献