Ultrasound Surveillance of Ectatic Abdominal Aortas

Author:

Devaraj S1,Dodds SR1

Affiliation:

1. Department of Vascular Surgery, Good Hope Hospital NHS Trust Sutton Coldfield, UK

Abstract

INTRODUCTION Some studies have considered abdominal aortas of 2.6–2.9 cm diameter (ectatic aortas) at age 65 years as being abnormal and have recommended surveillance, whereas others have considered these normal and surveillance unnecessary. It is, therefore, not clear how to manage patients with an initial aortic diameter between 2.6–2.9 cm detected at screening. The aim of this study was to evaluate growth rates of ectatic aortas detected on initial ultrasound screening to determine if any developed into clinically significant abdominal aortic aneurysms (AAAs; > 5.0 cm) and clarify the appropriate surveillance intervals for these patients. PATIENTS AND METHODS Data were obtained from a prospective AAA screening programme which commenced in 1992. The group of patients with initial aortic diameters of 2.6–2.9 cm with a minimum of 1-year follow-up were included in this study (Group 2). This was further divided into two subgroups (Groups 3a and 3b) based on a minimum follow-up interval obtained from outcome analysis. Mean growth rate was calculated as change in aortic diameter with time. The comparison of growth rates in Groups 3a and 3b was performed using the t-test. The number and proportion of AAAs that expanded to ≥ 3.0 cm and ≥ 5.0 cm in diameter were also calculated. RESULTS Out of 999 patients with AAA ≥ 2.6 cm with minimum 1-year follow-up, 358 (36%) were classified as ectatic aortas (2.6–2.9 cm) at initial ultrasound screening with the mean growth rate of 1.69 mm/year (95% CI, 1.56–1.82 mm/year) with a mean follow-up of 5.4 years. Of these 358 ectatic aortas, 314 (88%) expanded into ≥ 3.0 cm, 45 (13%) expanded to ≥ 5.0 cm and only 8 (2%) expanded to ≥ 5.5 cm over a mean follow-up of 5.4 years (range, 1–14 years). No ectatic aortas expanded to ≥ 5.0 cm within the first 4 years of surveillance. Therefore, the minimum follow-up interval was set at 4 years and this threshold was then used for further analysis. The mean growth rate in Group 3a (< 5.0 cm at last scan) was 1.33 mm/year (95% CI, 1.23–1.44 mm/year) with a mean follow-up of 7 years compared to Group 3b (≥ 5.0 cm at last scan) with the mean growth rate of 3.33 mm/year (95% CI 3.05–3.61 mm/year) and a mean follow-up of 8 years. The comparison of mean growth rates between Groups 3a and 3b is statistically significant (t-test; T = 13.00; P < 0.001). CONCLUSIONS One-third of patients undergoing AAA screening will have ectatic aortas (2.6–2.9 cm) and at least 13% of these will expand to a size of ≥ 5.0 cm over a follow-up of 4–14 years. A threshold diameter of 2.6 cm for defining AAAs in a screening programme is recommended and ectatic aortas detected at age 65 years can be re-screened at 4 years after the initial scan. A statistically significant difference was found in the growth rates of ectatic aortas with minimum 4 years follow-up, expanding to ≥ 5.0 cm compared to those less than 5.0 cm at last surveillance scan. Further studies are required to test the hypothesis of whether growth rate over the first 4 years of surveillance will identify those who are most likely to expand to a clinically significant size (> 5.0 cm).

Publisher

Royal College of Surgeons of England

Subject

General Medicine,Surgery

Cited by 32 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3