Hepatocyte growth factor as indicator for subclinical atherosclerosis

Author:

Sommer Philip12ORCID,Schreinlechner Michael1ORCID,Noflatscher Maria1,Engl Clarisse3,Lener Daniela1ORCID,Theurl Markus1ORCID,Kirchmair Rudolf1,Marschang Peter14ORCID

Affiliation:

1. Department of Internal Medicine III (Cardiology and Angiology), Medical University of Innsbruck, Austria

2. Department of Internal Medicine I (Cardiology, Angiology and Pulmology), Klinikum rechts der Isar, Technical University Munich, Germany

3. Department of Immunology, University of Pittsburgh, The Assembly, Pittsburgh, PA, USA

4. Department of Internal Medicine, Central Hospital of Bolzano (SADES-ASDAA), Teaching Hospital of Paracelsus Medical University (PMU), Bolzano, Italy

Abstract

Summary: Background: Hepatocyte growth factor (HGF) is a pleiotropic cytokine mainly produced by mesenchymal cells. After endothelial damage by oxidized low-density lipoprotein (LDL), HGF is produced and released into the circulation in response. Due to this mechanism HGF has been proposed as possible clinical biomarker for clinical as well as subclinical atherosclerosis. Patients and methods: The conducted study is an observational, single centre, cohort study, including 171 patients with at least one cardiovascular risk factor or already established cardiovascular disease (CVD). Each patient underwent 3D plaque volumetry of the carotid and femoral arteries as well as physical examination and record of the medical history. Additionally, plasma HGF and further laboratory parameters like high sensitivity C-reactive protein and LDL-cholesterol were determined. Results: 169 patients were available for statistical analysis. In bivariate correlation, HGF showed a highly significant correlation with total plaque volume (TPV, r=0.48; p<0.001). In receiver operating characteristic (ROC) analysis for high TPV, HGF showed an area under the curve (AUC) of 0.68 (CI 95%: 0.59–0.77, p<0.001) with a sensitivity of 78% and a specificity of 52% to predict high TPV at a cut-off of 959 ng/ml. In the ROC-analysis for the presence of CVD, HGF demonstrated an AUC of 0.65 (95% CI 0.55–0.73; p=0.01) with a sensitivity of 77% and a specificity of 52%. Conclusions: Higher plasma levels of HGF are associated with higher atherosclerotic plaque volume as measured by 3D-ultrasound.

Publisher

Hogrefe Publishing Group

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3