Das Einheilungsverhalten schmalkalibriger Gefäßprothesen aus Polyester mit plasminbehandelter Fibrinbeschichtung – eine experimentelle Untersuchung

Author:

Pfeiffer Thomas1,Kever 1,Grabitz 1,Reiher 1,Müller 2,Hildebrand 2,Sandmann 1

Affiliation:

1. Department of Vascular Surgery and Kidney Transplantation, Heinrich-Heine-University, Düsseldorf, Germany

2. Institute of Pathology, University Clinic Bergmannsheil, Bochum, Germany

Abstract

Background: The autogenous vein represents the graft material of choice in crural and pedal bypass surgery. Because of the numerous problems concerning the graft harvesting and the quality of autogenous vein material an equally good allogenous graft is urgently needed. Up to the present times no such graft material has been able to achieve the success of vein grafts. Methods: We investigated the knitted polyester prosthesis Terumo PF-V (Terumo Comp., Japan), diameter 5 mm with outer reinforce, which is characterized by a new coating of plasmin-treated fibrin. Grafts were implanted as bypass into the ligated carotid (n=10) and femoral arteries (n=10) of 10 dogs (beagles). As a control 5 mm-ePTFE-prostheses (Impra Carboflo) were implanted simultaneously on the contralateral side. Results: After 6 months, seven of 20 PF-V-grafts and 8 of 20 PTFE-grafts were patent. All prostheses presented with good macroscopic healing characteristics. In the patent grafts, angiography showed no substantial stenoses. The histological examination of the material was performed using light microscopy, transmission polarising microscopy, scanning electron microscopy, and transmission electron microscopy. Both types of prostheses showed the typical pattern of graft healing by migration of mesenchymal cells through the prosthesis, formation of capillaries, and growing of a neointima with endothelium-like cells. All failed bypass grafts presented with an occluding proliferation from the arterial wall into the anastomotic region. Conclusions: Using clinically or histologically evaluation, neither graft demonstrated superiority over the other. The results indicate that the coating plays only a minor role for graft healing if any. For proper graft function, the arterial wall proliferation at the anastomotic region, which is not dependent on the type of prosthesis, appears to be most important. The overall results concerning both types of prostheses were disappointing

Publisher

Hogrefe Publishing Group

Subject

Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3