BioMimics 3D vascular stent system for femoropopliteal interventions

Author:

Lichtenberg Michael1ORCID,Zeller Thomas2,Gaines Peter3,Piorkowski Michael4

Affiliation:

1. Vascular Center, Klinikum Hochsauerland, Arnsberg, Germany

2. Universitätsklinikum Freiburg Herzzentrum, Bad Krozingen, Germany

3. Sheffield Hallam University, Sheffield, UK

4. Cardioangiologisches Centrum Bethanien, Frankfurt, Germany

Abstract

Summary: Background: The MIMICS-3D study aimed to assess the safety and effectiveness of the BioMimics 3D Vascular Stent System for the treatment of symptomatic femoropopliteal artery disease in a real-world patient population. Patients and methods: Consecutive participants who were scheduled for implantation of the BioMimics 3D stent were enrolled in the prospective, observational, multicenter study. The primary effectiveness outcome was freedom from clinically driven target lesion revascularization at 12 months and the primary safety outcome was a composite of major adverse events comprising death, major target limb amputation, or clinically driven target lesion revascularization at 30 days. Outcomes through 24 months are reported. Results: A total of 507 patients (70±10 years, 65.5% male sex) were enrolled and treated with the study stent. 24.0% had critical limb-threatening ischemia, lesion length was 127±92 mm, and 56.8% of lesions were totally occluded. The Kaplan-Meier (KM) estimate of freedom from clinically driven target lesion revascularization at twelve-months was 90.6% (95% CI: 87.9%–93.3%) and the 30-day primary safety outcome occurred in 1.2% (95% CI: 0.5%–2.7%) of participants. At 24 months, clinical improvement was achieved in 86.6% and the KM estimate of freedom from clinically driven target lesion revascularization was 82.8% (95% CI: 79.4%–86.4%). The KM estimate of freedom from loss of primary patency according to PSVR >2.4 was 78.6% (95% CI: 74.7%–82.4%). Survival distribution functions regarding primary patency were lower with long lesions (>150 mm; log-rank p<0.001) but did not differ significantly between participants with or without critical limb-threatening ischemia (log-rank p=0.07). Conclusions: Endovascular treatment of atherosclerotic femoropopliteal lesions with the BioMimics 3D Vascular Stent System is efficacious and safe in a real-world setting.

Publisher

Hogrefe Publishing Group

Subject

Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3