Use of biosynthetic prosthesis (Omniflow II®) to replace infected infrainguinal prosthetic grafts - first results

Author:

Töpel 1,Betz 1,Uhl 1,Wiesner 1,Bröckner 1,Steinbauer 1

Affiliation:

1. Vascular Surgery, Krankenhaus Barmherzige Brüder Regensburg, Germany

Abstract

Background: The current treatment standard of infected infrainguinal prosthetic vascular grafts includes total graft explantation and autologous vascular reconstruction. In the absence of appropriate autologous venous graft material prosthetic grafts with increased bacterial resistance can be used, whereas reinfection rates are still higher than after autologous reconstruction. Biosynthetic grafts have shown low postoperative infection rates when used as elective bypass material. Their higher resistance to bacterial infection could make them an alternative to replace infected prosthetic grafts in the absence of autologous material. Patients and methods: Between November 2009 and April 2011, 7 patients with infected infrainguinal prosthetic grafts (Szilagyi 3; 3 supragenicular and 4 infragenicular reconstructions) presented to our institution. There were 4 early (< 3 months after implantation) and 3 late infections (> 3 months after implantation. All grafts were explanted and replaced by biosynthetic grafts (Omniflow II®), because the patient had no suitable peripheral vein for complete autologous replacement. In 2 cases a composite graft with greater saphenous vein was done. In 6 cases microbiological cultures from intraoperatively obtained species were positive. The initial broad spectrum antibiotic therapy was continued according to the antibiogram for 6 to12 weeks. Results: There was no early or late reinfection during follow up (mean 9 months, range 4 - 20 months). During follow up we observed graft occlusions in 3 patients (1 due to kinking of the bypass, 1 due to progressive artheriosclerotic occlusion of the outflow vessels and 1 iatrogenic by external compression with a pressure cuff during arthroscopy). There were no early or late major amputations. One patient died with pneumonia 11 months postoperatively. Conclusions: In the absence of appropriate autologous material biosynthetic grafts seem to be a possible alternative to replace infected infrainguinal grafts. The different mechanical properties of biosynthetic grafts may be of certain disadvantage in infragenicular reconstructions.

Publisher

Hogrefe Publishing Group

Subject

Cardiology and Cardiovascular Medicine

Cited by 39 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3