First clinical experience with the Multi-LOC multiple stent delivery system for focal stenting in long femoro-popliteal lesions

Author:

Amendt Klaus1,Beschorner Ulrich2,Waliszewski Matthias34,Sigl Martin1,Langhoff Ralf5,Thalwitzer Jörg6,Redlich Ulf7,Vogel Britta8,Härtel Dirk9,Zeller Thomas2

Affiliation:

1. Klinik für Angiologie, Kardiologie, Diakonissenkrankenhaus Mannheim, Germany

2. Universitäts-Herzzentrum Freiburg, Bad Krozingen GmbH, Bad Krozingen, Germany

3. Medical Scientific Affairs, B.Braun Melsungen AG, Berlin, Germany

4. Department of Cardiology, Charité – Universitätsmedizin Berlin, Campus Virchow, Berlin, Germany

5. Angiologie, Sankt-Gertrauden-Krankenhaus, Berlin, Germany

6. Institut für diagnostische und interventionelle Radiologie und Neuroradiologie, Heinrich-Braun-Klinikum Zwickau, Germany

7. Institut für diagnostische und interventionelle Radiologie, Klinikum Magdeburg, Germany

8. Innere Medizin III, Kardiologie, Angiologie und Pneumologie, Universität Heidelberg, Germany

9. Kardiologie, Angiologie und Intensivmedizin, Klinikum Lippe GmbH, Detmold, Germany

Abstract

Abstract. Background: The purpose of this observational study is to report the six-month clinical outcomes with a new multiple stent delivery system in patients with femoro-popliteal lesions. Patients and methods: The LOCOMOTIVE study is an observational multicentre study with a primary endpoint target lesion revascularization (TLR) rate at six months. Femoro-popliteal lesions were prepared with uncoated and/or paclitaxel-coated peripheral balloon catheters. When flow limiting dissections, elastic recoil or recoil due to calcification required stenting, up to six short stents per delivery device, each 13 mm in length, were implanted. Sonographic follow-ups and clinical assessments were scheduled at six months. Results: For this first analysis, a total of 75 patients 72.9 ± 9.2 years of age were enrolled. The majority of the 176 individually treated lesions were in the superficial femoral artery (76.2 %, 134/176) whereas the rate of TASC C/D amounted to 51.1 % (90/176). The total lesion length was 14.5 ± 9.0 cm with reference vessel diameters of 5.6 ± 0.7 mm. Overall 47 ± 18 % of lesion lengths could be saved from stenting. At six months, the patency was 90.7 % (68/75) and all-cause TLR rates were 5.3 % (4/75) in the overall cohort. Conclusions: The first clinical experience at six months suggests that the MSDS strategy was safe and effective to treat femoro-popliteal lesions of considerable length (14.5 ± 9.0 cm). Almost half of the lesion length could be saved from stenting while patency was high and TLR rates were acceptably low.

Publisher

Hogrefe Publishing Group

Subject

Cardiology and Cardiovascular Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3