The Effect of Food-Simulating Liquids and Thermal Aging on Surface Roughness and Color Stability of Bulk-Fill and Conventional Composites

Author:

KILIÇ Vahti1ORCID,HÜRMÜZLÜ Feridun2ORCID,KAPTAN Alper3ORCID

Affiliation:

1. ERCİYES ÜNİVERSİTESİ, DİŞ HEKİMLİĞİ FAKÜLTESİ, KLİNİK BİLİMLER BÖLÜMÜ, RESTORATİF DİŞ TEDAVİSİ ANABİLİM DALI

2. LOKMAN HEKİM ÜNİVERSİTESİ DİŞ HEKİMLİĞİ FAKÜLTESİ RESTORATİF DİŞ TEDAVİSİ ANABİLİM DALI

3. SİVAS CUMHURİYET ÜNİVERSİTESİ, DİŞ HEKİMLİĞİ FAKÜLTESİ, KLİNİK BİLİMLER BÖLÜMÜ, RESTORATİF DİŞ TEDAVİSİ ANABİLİM DALI

Abstract

Objectives: The aim of this study was to evaluate the effect of food-simulating liquids (FSLs) and thermal aging on the surface roughness and color stability of bulk-fill and conventional composites. Materials and Methods: A total of 320 disc-shaped samples were prepared, with 40 samples from each of 4 different bulk-fill composites (Filtek Bulk Fill, X-tra fil, Beautifil Bulk Restorative, and Estelite Bulk Fill Flow), and 4 conventional nano-filled composite resins (Filtek Z550, CeramX SphereTEC one, Admira, and Kalore). The prepared samples were randomly divided into subgroups for exposure to FSLs (ethanol, heptane, citric acid) and thermal cycling (TC) (n=10 per subgroup) for 28 days. Initial profilometric surface roughness measurements (Ra0) of all samples and AFM and SEM analyses of selected samples were followed by exposure to FSLs and TC. After completion of aging protocols, measurements and analyses were repeated to obtain the Ra1 (post-treatment surface roughness), and change in surface roughness (∆Ra1-0) was then calculated. Subsequently, initial color measurement of the samples was conducted using a spectrophotometer, followed by immersion of the samples in a coffee solution for 24 hours. Color measurements were repeated, and color change (∆E) was calculated. Two-way repeated measures ANOVA was used to compare Ra0 and Ra1 values and one-way ANOVA for comparing ∆Ra and ∆E values. Tukey and post hoc tests were employed for pairwise comparisons. The significance level was set at α=.05. Results: While the surface roughness of bulk-fill composites was affected by the protocols applied (p<0.05), conventional composites generally remained unaffected. Bulk-fill composites exhibited greater ΔRa and ∆E values. The highest ∆Ra and ∆E values were observed in the Beautifil Bulk Restorative group, with the greatest discoloration seen after immersion in citric acid. Conclusions: Thermal cycling and immersion in FSLs affect surface roughness and color stability of composite resins depending on the content and structure of the composites.

Funder

CÜBAP

Publisher

Cumhuriyet University

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3