Recommendations on measurement and analysis of results obtained on biological substances using isothermal titration calorimetry (IUPAC Technical Report)

Author:

Schwarz Frederick P.1,Reinisch Timm2,Hinz Hans-Jürgen2,Surolia Avadhesha3

Affiliation:

1. 1Center for Advanced Research in Biotechnology/National Institute of Standards and Technology, 9600 Gudelsky Drive, Rockville, Maryland 20850, USA

2. 2Institut für Physikalische Chemie, Westfalische Wilhelms-Universität, Schlossplatz 4/7 D-48149, Münster, Germany

3. 3National Institute of Immunology, Aruna Asaf Ali Marg, New Delhi, India-110067

Abstract

Isothermal titration calorimetry (ITC) is widely used to determine the thermodynamics of biological interactions including protein-protein, small molecule-protein, protein-DNA, small molecule-DNA, and antigen-antibody interactions. An ITC measurement consists of monitoring the transfer of heat between an analyte solution in a sample vessel and a reference solution in a reference vessel upon injection of a small aliquot of titrant solution into the sample vessel at a fixed ITC operating temperature. A binding isotherm is generated from the heat-transferred-per-injection data and values for the binding constants, the apparent binding enthalpies, and the apparent ratio of the amount of titrant to analyte for the binding reaction are then determined from fits of a binding model, whether it is a single site, identical multi-site, or an interacting multi-site binding model, to the binding isotherm. Prior to the fitting procedure, corrections should be made for contributions from extraneous heat of mixing determined separately from injections of the titrant into just the dialysate/buffer solution. Ultra-high binding constants, which cannot be directly determined from an ITC measurement, can be determined by a displacement ITC method where injections of the tight-binding titrant into a solution of a weaker-binding titrant-analyte complex displaces the weaker-binding titrant from the complex. The Michaelis and catalytic constants can be determined for an enzyme reaction from injections of a substrate or enzyme titrant into an enzyme or substrate analyte solution. Several binding reactions are suggested to check the operating performance of the ITC. The reporting of ITC results must be specific with regard to the composition of the titrant and the analyte solutions, the temperature, and the model used in the analysis.

Publisher

Walter de Gruyter GmbH

Subject

General Chemical Engineering,General Chemistry

Reference45 articles.

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3