Development of a Validated High-Performance Liquid Chromatographic Method in Reverse Phase for Simultaneously Determining Triamcinolone Acetonide and Benzyl Alcohol in Injectable Suspension.
-
Published:2021-08-30
Issue:4
Volume:37
Page:938-948
-
ISSN:2231-5039
-
Container-title:Oriental Journal Of Chemistry
-
language:en
-
Short-container-title:Orient. J. Chem
Author:
Tiwari Vivek1, Mishra S.K.2
Affiliation:
1. Department of Chemistry, Jiwaji University Gwalior (M.P.), 474001, India. 2. 2Department of Chemistry, Government P.G. College, Datia( M.P.)475661 India.
Abstract
A high-performance liquid chromatographic stability-indicating assaymethod in reverse-phase has been developed and validated for the simultaneous qualitative and quantitative measurement of triamcinolone acetonide and benzyl alcohol content in injectable suspension. The reverse-phase method was developed by using Inertsil ODS-2 column(100 x 4.6mm),5μm. with a mobile phase ratio comprised of water and acetonitrile mixed in 70:30 v/v ratio and pumped at a flow rate of 1.5 ml/min where the temperature of the column oven controlled at 40°C and sample compartment at 5°C with 10μL injection volume. Benzyl Alcohol and Triamcinolone Acetonide had retention times of 1.80 and 5.60 minutes, respectively with UV detection for benzyl alcohol at 215 nm and triamcinolone acetonide at 254 nm. The guidelines of the International Conference on Harmonization were used for the validation of this novel method. During validation, the developed approach was shown to be exact, accurate, linear, robust, rugged, and stable. The detector was showing linear response in a range of 10 µg/mlto 120 µg/ml and 2.5 µg/ml to 30 µg/ml for triamcinolone Acetonide and benzoyl alcohol respectively.
Publisher
Oriental Scientific Publishing Company
Subject
Drug Discovery,Environmental Chemistry,Biochemistry,General Chemistry
Reference19 articles.
1. 1. Paik, J.; Duggan, S. T.; Keam, S. J. Drugs2019, 79 (4), 455–462. 2. 2. Meykadeh, N.; Hengge, U. R. Hautarzt2003, 54 (7), 641–661. 3. 3. Johnson, W.; Bergfeld, W. F.; Belsito, D. V.; Hill, R. A.; Klaassen, C. D.; Liebler, D. C.; Marks, J. G.; Shank, R. C.; Slaga, T. J.; Snyder, P. W.; Andersen, F. A. Int. J. Toxicol.2017, 36 (3_suppl), 5S-30S. 4. 4. Döppenschmitt, S. A.; Scheidel, B.; Harrison, F.; Surmann, J. P. J. Chromatogr. B Biomed. Appl.1996, 682 (1), 79–88. 5. 5. van Heugten, A. J. P.; de Boer, W.; de Vries, W. S.; Markesteijn, C. M. A.; Vromans, H. J. Pharm. Biomed. Anal.2018, 149, 265–270.
|
|