Cole Parameter Estimation from the Modulus of the Electrical Bioimpeadance for Assessment of Body Composition. A Full Spectroscopy Approach

Author:

Buendia R.123,Gil-Pita R.2,Seoane F.13

Affiliation:

1. School of Engineering, University of Borås , SE-501 90 Borås , Sweden

2. Department of Signal Theory and Communications, University of Alcala , ES-28871 , Madrid , Spain

3. School of Technology and Health, Royal Institute of Technology , SE-141 52 , Huddinge , Sweden

Abstract

Abstract Activities around applications of Electrical Bioimpedance Spectroscopy (EBIS) have proliferated in the past decade significantly. Most of these activities have been focused in the analysis of the EBIS measurements, which eventually might enable novel applications. In Body Composition Assessment (BCA), the most common analysis approach currently used in EBIS is based on the Cole function, which most often requires curve fitting. One of the most implemented approaches for obtaining the Cole parameters is performed in the impedance plane through the geometrical properties that the Cole function exhibit in such domain as depressed semi-circle. To fit the measured impedance data to a semi-circle in the impedance plane, obtaining the Cole parameters in an indirect and sequential manner has several drawbacks. Applying a Non-Linear Least Square (NLLS) iterative fitting on the spectroscopy measurement, obtains the Cole parameters considering the frequency information contained in the measurement. In this work, from experimental total right side EBIS measurements, the BCA parameters have been obtained to assess the amount and distribution of whole body fluids. The values for the BCA parameters have been obtained using values for the Cole parameters estimated with both approaches: circular fitting on the impedance plane and NLLS impedance-only fitting. The comparison of the values obtained for the BCA parameters with both methods confirms that the NLLS impedance-only is an effective alternative as Cole parameter estimation method in BCA from EBIS measurements. Using the modulus of the Cole function as the model for the fitting would eliminate the need for performing phase detection in the acquisition process, simplifying the hardware specifications of the measurement instrumentation when implementing a bioimpedance spectrometer.

Publisher

Walter de Gruyter GmbH

Subject

Biomedical Engineering,Biophysics

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3