False Prolongation of Activated Partial Thromboplastin Time with Aminoglycoside Antimicrobial Agents: A Case Report

Author:

Doi HirokiORCID,Osawa Michiko,Ozaki Ayane,Sato Seiko,Fujita Takashi,Akiyama Hidehiko,Ito HiroyasuORCID

Abstract

BACKGROUND: Activated partial thromboplastin time (APTT) is a clotting time assay for screening bleeding tendency, evaluating coagulation factor production capacity, assessing preoperatively, monitoring anticoagulant drugs, and searching for blood coagulation abnormalities such as hemophilia and antiphospholipid syndrome. CASE PRESENTATION: Here, we present a 77-year-old male patient with dyspnea who was suspected to have a drug-resistant Pseudomonas aeruginosa infection and pulmonary mycosis. The patient had no history of bleeding tendencies or anticoagulant medication use. The laboratory test results revealed an abnormally prolonged activated partial thromboplastin time (APTT) of 120.3 s using the Coagpia® APTT-N reagent. The APTT test is frequently used to evaluate blood clotting function and assess for bleeding disorders. Prolonged APTT can indicate coagulation factor deficiencies or the presence of certain conditions such as von Willebr and disease, hemophilia, and disseminated intravascular syndrome. However, APTT standardization has not been achieved, causing discrepancies in test results due to variations in the reagents used. The prolonged APTT, in this case, was initially suspected to be caused by contamination or other artifacts, but repeat blood collections and cross-mixing tests revealed the Coagpia® APTT-N reagent as the cause of false prolongation. The reagent was changed to HemosIL SynthASil APTT, which revealed a normal APTT result. The patient had been receiving the aminoglycoside antimicrobial agent tobramycin, and the blood sample taken at the peak tobramycin level demonstrated the longest APTT time. The APTT shortened over time, corresponding to the decrease in tobramycin blood levels. CONCLUSION: Overall, this paper reports a case of false APTT prolongation due to a specific APTT reagent in the presence of aminoglycoside antimicrobial agents. The findings underscore the difficulties in standar PTT testing and the importance of considering reagent performance characteristics in result interpretations.

Publisher

Scientific Foundation SPIROSKI

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3