Comparison of Glomerular Filtration Rate Measurement Methods between Radionuclide in vivo Scintigraphic Gates’ and Plasma Sampling

Author:

Hussein Mai,Younis Jehan,Moustafa Hosna,Elantably Ismail

Abstract

AIM: To correlate between the radionuclide in vitro plasma sampling method (using single and dual blood samples) and Gates’ GFR measurement using Tc-99m diethylene triamine penta-acetic acid (Tc-99m DTPA) renal scintigraphy (in vivo method). METHODS: This study included 40 renal donors (group 1) and 40 patients with obstructive uropathy (group 2). Group 1 included 22 males and 18 females with an age range from 22 to 65 years, while group 2 included 24 males and 16 females with age range 27 to 64 years. Both groups subjected to renal Scintigraphy after administration of 5 mCi 99m-Tc DTPA, GFR was calculated using Gates’ method (in vivo method), then plasma sampling was acquired at 60 mins and 180 mins post-injection of the tracer, samples were counted in well counter and GFR was calculated using in vitro technique either using single plasma sample (SPSM 60 mins) or dual sample (DPSM 60 & 180 min). Additionally, GFR was measured by estimated equations based on serum creatinine. RESULTS: In group 1, the mean GFR using in vivo Gates’ method was 115.7 ± 29 ml/min, while using the SPSM was 100.1 ± 16.1 ml/min, and the DPSM was 100.3 ± 20.1 ml/min. In group 2, mean GFR using in vivo method was 74.1 ± 14.5 ml/min, while using in vitro SPSM it was 77.5 ± 24.9 ml/min and DPSM was 76.8 ± 24.8 ml/min. There was no significant difference between mean GFR values using in vivo and in vitro methods (single or dual samples) in group 1 and 2 (p > 0.05). There is high significant correlation between SPSM and DPSM in groups 1 and 2 (r = 0.90, r = 0.91 respectively), moderate significant correlation was found between in vivo Gates’ method and in vitro SPSM in group 1 and 2 (r = 0.46 and 0.57 respectively) and moderate correlation was evident between in vivo and in vitro DPSM in both groups (r = 0.42 and 0.68 respectively). By using the DPSM as the reference standard significant high correlation was found with SPSM and significant-high moderate correlation with in vivo Gates’ scintigraphic method. Conclusion: In vitro plasma sampling considered as a reliable, accurate |method for GFR calculation yet it considered relatively complex, both single and dual sample in vitro techniques showed a very high correlation, and hence SPSM can replace DPSM. CONCLUSION: Renal scintigraphy and GFR estimation using Gates’ in vivo method is considered inaccurate, yet given its simplicity in performance it can still be used if corrected GFR is standardised for Egyptian population-based on studies with large numbers of patients from multiple centres.

Publisher

Scientific Foundation SPIROSKI

Subject

General Medicine

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3