Author:
Hussein Mai,Younis Jehan,Moustafa Hosna,Elantably Ismail
Abstract
AIM: To correlate between the radionuclide in vitro plasma sampling method (using single and dual blood samples) and Gates’ GFR measurement using Tc-99m diethylene triamine penta-acetic acid (Tc-99m DTPA) renal scintigraphy (in vivo method).
METHODS: This study included 40 renal donors (group 1) and 40 patients with obstructive uropathy (group 2). Group 1 included 22 males and 18 females with an age range from 22 to 65 years, while group 2 included 24 males and 16 females with age range 27 to 64 years. Both groups subjected to renal Scintigraphy after administration of 5 mCi 99m-Tc DTPA, GFR was calculated using Gates’ method (in vivo method), then plasma sampling was acquired at 60 mins and 180 mins post-injection of the tracer, samples were counted in well counter and GFR was calculated using in vitro technique either using single plasma sample (SPSM 60 mins) or dual sample (DPSM 60 & 180 min). Additionally, GFR was measured by estimated equations based on serum creatinine.
RESULTS: In group 1, the mean GFR using in vivo Gates’ method was 115.7 ± 29 ml/min, while using the SPSM was 100.1 ± 16.1 ml/min, and the DPSM was 100.3 ± 20.1 ml/min. In group 2, mean GFR using in vivo method was 74.1 ± 14.5 ml/min, while using in vitro SPSM it was 77.5 ± 24.9 ml/min and DPSM was 76.8 ± 24.8 ml/min. There was no significant difference between mean GFR values using in vivo and in vitro methods (single or dual samples) in group 1 and 2 (p > 0.05). There is high significant correlation between SPSM and DPSM in groups 1 and 2 (r = 0.90, r = 0.91 respectively), moderate significant correlation was found between in vivo Gates’ method and in vitro SPSM in group 1 and 2 (r = 0.46 and 0.57 respectively) and moderate correlation was evident between in vivo and in vitro DPSM in both groups (r = 0.42 and 0.68 respectively). By using the DPSM as the reference standard significant high correlation was found with SPSM and significant-high moderate correlation with in vivo Gates’ scintigraphic method. Conclusion: In vitro plasma sampling considered as a reliable, accurate |method for GFR calculation yet it considered relatively complex, both single and dual sample in vitro techniques showed a very high correlation, and hence SPSM can replace DPSM.
CONCLUSION: Renal scintigraphy and GFR estimation using Gates’ in vivo method is considered inaccurate, yet given its simplicity in performance it can still be used if corrected GFR is standardised for Egyptian population-based on studies with large numbers of patients from multiple centres.
Publisher
Scientific Foundation SPIROSKI
Cited by
5 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献