Aortic Annulus Enlargement: Early and Long-Terms Results

Author:

Dumani Selman,Likaj Ermal,Dibra Laureta,Beca Vera,Kuci Saimir,Refatllari Ali

Abstract

AIM: Patient-prosthesis mismatch (PPM) is a common occurrence in aortic valve surgery. Even the discussions about the impact of this phenomenon on the results of aortic valve surgery, the management of this problem remain one of the main topics in this kind of surgery. One of the ways of a solution is aortic annulus enlargement. The main topic of this study is to evaluate the early and longterm results of this technique in our country.METHODS: During the period January 2010 –January 2015, 641 patients performed aortic valve surgery. In ten patients we performed aortic annulus enlargement according to Manouguian technique to avoid severe patient-prothesis mismatch.Operative mortality and perioperative complications (low cardiac output, pulmonary complications, etc..) were considered the indicators of the early results. Survival, clinical presentation according to NYHA, quality of life were the indicators to evaluate long-term results. Preoperative and postoperative echocardiographic data were also used to evaluate our results. We collected the data from hospital registrations and periodical clinical visit and echographic examination after hospital discharge.RESULTS: In our group, 6 of 10 patients were diagnosed with stenotic aortic valve, two patients had aortic valve regurgitation and two mixed valve pathology. Four patients had concomitant cardiac surgery procedure, mitral or CABG. In all cases, aortic valve pathology was the primary diagnose.In the preoperative echocardiographic examination mean transvalvular gradient was 54.3 ± 6.42.We had no death during early or late postoperative period. Only one patient had pulmonary complications and long time of respiratory assistance because of his pulmonary pathology.The same patient had low cardiac output and wound infection. Early after surgery mean transprostethic gradient was 16.2 ± 3.44 and late postoperative was 15.9 ± 4.3. No patient had the severe patient-prothesis mismatch. Mean follow-up was 49 ± 20.26 months. During follow-up, we had no death, and all patients had very good quality of life.CONCLUSIONS: Aortic valve annulus enlargement can be used with very good early and late results with the final goal to increase the potential benefit of the patient from surgery of aortic valve.

Publisher

Scientific Foundation SPIROSKI

Subject

General Medicine

Cited by 6 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3