The top-down approach to measurement uncertainty

Author:

Martinello Flávia1,Snoj Nada2,Skitek Milan2,Jerin Aleš2

Affiliation:

1. Department of Clinical Analysis, Federal University of Santa Catarina, Florianopolis, Brazil

2. Institute of Clinical Chemistry and Biochemistry, University Medical Centre Ljubljana, Ljubljana, Slovenia

Abstract

Introduction: By quantifying the measurement uncertainty (MU), both the laboratory and the physician can have an objective estimate of the results’ quality. There is significant flexibility on how to determine the MU in laboratory medicine and different approaches have been proposed by Nordtest, Eurolab and Cofrac to obtain the data and apply them in formulas. The purpose of this study is to compare three different top-down approaches for the estimation of the MU and to suggest which of these approaches could be the most suitable choice for routine use in clinical laboratories. Materials and methods: Imprecision and bias of the methods were considered as components of the MU. The bias was obtained from certified reference calibrators (CRC), proficiency tests (PT), and inter-laboratory internal quality control scheme (IQCS) programs. The bias uncertainty, the combined and the expanded uncertainty were estimated using the Nordtest, Eurolab and Cofrac approaches. Results: Using different approaches, the expanded uncertainty estimates ranged from 18.9-40.4%, 18.2-22.8%, 9.3-20.9%, and 7.1-18.6% for cancer antigen (CA) 19-9, testosterone, alkaline phosphatase (ALP), and creatinine, respectively. Permissible values for MU and total error ranged from 16.0-46.1%, 13.1-21.6%, 10.7-26.2%, and 7.5-17.3%, respectively. Conclusion: The bias was highest using PT, followed by CRC and IQCS data, which were similar. The Cofrac approach showed the highest uncertainties, followed by Eurolab and Nordtest. However, the Eurolab approach requires additional measurements to obtain uncertainty data. In summary, the Nordtest approach using IQCS data was therefore found to be the most practical formula.

Publisher

Croatian Society for Medical Biochemistry and Laboratory Medicine

Subject

Biochemistry (medical),Clinical Biochemistry

Reference28 articles.

1. Bureau International des Pois et Mesures. JCGM 200:2012, International vocabulary of metrology – basic and general concepts and associated terms (VIM). Available at: http://www.bipm.org/en/publications/guides/vim.html. Accessed: November 17th 2019.

2. Measurement uncertainty: Friend or foe?;Infusino;Clin Biochem,2018

3. Uncertainty in measurement and total error - are they so incompatible?;Farrance;Clin Chem Lab Med,2016

Cited by 19 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3