Time-dependent variation of ionized calcium in serum samples

Author:

Perović Antonija1,Njire Bratičević Marina1

Affiliation:

1. Department of Laboratory Diagnostics, Dubrovnik General Hospital, Dubrovnik, Croatia

Abstract

Introduction: The aim of this study was to compare ionized calcium (iCa) concentrations in arterial heparinized blood and venous serum and to investigate time-dependent variation of iCa in serum samples centrifuged and analysed at different times. Materials and methods: Ionized calcium was measured (N = 25) in arterial blood within 20 min after puncture, and in serum within 10 min after centrifugation conducted 30 min after sampling. Effect of time between sampling and centrifugation was examined in three tubes (N = 30) centrifuged 15, 30 and 60 min after sampling, and analysed within 10 min. Effect of time between centrifugation and analysis was investigated in three tubes (N = 31) centrifuged 30 min after sampling and analysed: 0-10, 30-40 and 90-100 min after centrifugation. Ionized calcium was measured on the Siemens RapidLab 348EX analysers. Statistical significance was tested using Wilcoxon test and ANOVA analysis. Clinical significance was judged against reference change values (RCV). Results: No statistically significant difference was found between iCa in arterial blood and serum (P = 0.274). A statistically significant decrease was found: in tubes centrifuged 60 and 15 min after sampling versus 30 min (P = 0.005, P = 0.003); and in tubes analysed 30-40 and 90-100 min after centrifugation versus 0-10 min (P = 0.021, P = 0.027). Clinically significant changes were observed: 60 versus 30 min (centrifugation) and 90-100 versus 0-10 and 30-40 min (analysis). Conclusions: Timely analysed arterial blood and serum samples can be used interchangeably. To avoid clinically significant variations, serum tubes should be centrifuged within 30 min after sampling, and analysis should be performed within 30 min after centrifugation.

Publisher

Croatian Society for Medical Biochemistry and Laboratory Medicine

Subject

Biochemistry, medical,Clinical Biochemistry

Cited by 5 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3