Introduction: Inappropriate laboratory retesting can be addressed by implementing minimum retesting intervals (MRI). The aim of our study was to assess the effectiveness of the implemented MRI protocol for inpatients. Materials and methods: Minimum retesting intervals were applied for 53 laboratory tests. The overall reduction of test requests, reduction in charges and reagent cost savings, frequency of MRI alert appearance as well as the rate of MRI acceptance and ignorance were calculated for a one-year period. Reasons for violating the MRI rule, hospital departments that contributed mostly to MRI rule violation, and the frequency of MRI violations between routine and emergency laboratory were evaluated. Results: During the one-year period, 106,780 requests violated the MRI rule, which corresponds to 14.8% of all requests received. 13,843 requests were cancelled, yielding a 1.9% reduction of requested tests. High-volume tests, namely complete blood count, C-reactive protein, alanine aminotransferase, gamma-glutamyltransferase and total bilirubin, accounted for 65% of all generated alerts and had the highest alert ignorance (>85%). The highest cancellation rate was observed for tumor markers and autoimmunity tests, for most being at least 50%. Annual charge reduction was 62,641 EUR while reagent cost savings were 11,408 EUR. Tests performed in the emergency laboratory had a higher alert appearance than the same routine tests. The most common reason for MRI violation was clinical justification based on the patient’s condition. Most frequently ignored MRI alerts were in the intensive care unit. Conclusion: MRI implementation showed limited effectiveness in reducing testing repetition and achieving financial savings, yet provided the basis for future improvements.

Publisher

Croatian Society for Medical Biochemistry and Laboratory Medicine

Subject

Biochemistry, medical,Clinical Biochemistry

Cited by 9 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3