Utility of icteric index in clinical laboratories: more than a preanalytical indicator

Author:

Mondejar Rufino1ORCID,Mayor Reyes María1,Melguizo Madrid Enrique1,Cañavate Solano Consuelo1,Pérez Ramos Santiago1

Affiliation:

1. UGC Laboratory

Abstract

Total bilirubin tests are highly demanded in clinical laboratories. Since icteric index (I-index) has zero cost, we aimed to evaluate its clinical utility and cost-effectiveness to determine if total bilirubin is necessary to be tested. We took into account if haemolysis could interfere to icteric index determination. Retrospectively we reviewed I-index results in two cohorts (43,372 and 8507 non-haemolysed and haemolysed samples, respectively). All determinations were done using Alinity c chemistry analysers (Abbott Diagnostics). Receiver operating characteristic (ROC) curve was used to determine the optimal index cut-off to discriminate between normal and abnormal bilirubin concentration (20.5 µmol/L). The ROC curve analysis suggested 21.4 µmol/L as the optimal I-index cut-off but differences in sensitivity and specificity were detected between patient derivation. For rejecting purpose, 15.4 µmol/L and 17.1 µmol/L I-index thresholds were selected based on patient derivation (inpatients and emergency room; and primary care and outpatients, respectively) with 97% sensitivity and 0.25% false negative results. Sensitivity was much lower in haemolysed samples. We selected 34.2 µmol/L I-index as threshold to detect hyperbilirubinemia with 99.7% specificity and 0.26% false positive results, independent of haemolysis. With the icteric index cut-offs proposed, we would save 66% of total bilirubin requested and analyse total bilirubin in around 2% of samples without total bilirubin requested. This study supports the use of I-index to avoid bilirubin determination and to identify patients with hyperbilirubinemia. This work considers that the economic and test savings could help to increase the efficiency in clinical laboratories.

Publisher

Croatian Society for Medical Biochemistry and Laboratory Medicine

Subject

Biochemistry (medical),Clinical Biochemistry

Reference23 articles.

1. Systematic Assessment of the Hemolysis Index: Pros and Cons.;Lippi;Adv Clin Chem,2015

2. Serum indices: managing assay interference.;Farrell;Ann Clin Biochem,2016

3. Current Methods of Haemolysis Detection and Reporting as a Source of Risk to Patient Safety: a Narrative Review.;McCaughey;Clin Biochem Rev,2016

4. Development of an integrated reporting system for verifying hemolysis, icterus, and lipaemia in clinical chemistry results.;Shin;Ann Lab Med,2014

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3