Rapid Detection of Salmonellae by Means of a New Impedance-Splitting Method

Author:

PLESS P.1,FUTSCHIK K.2,SCHOPF E.1

Affiliation:

1. 1Institute of Meat Hygiene and Technology, University of Veterinary Medicine, Linke Bahngasse 11, A-1030 Vienna, Austria

2. 2Institute of Fundamentals and Theory of Electrotechnics, Bioelectricity and Magnetism Division, University of Technology Gußhausstraße 27, A-1040 Vienna, Austria

Abstract

An Impedance-Splitting method is proposed for the rapid detection of salmonellae in foods. The measuring System, BacTrac™ 4100, permits the registration of changes, caused by bacterial metabolism, not only of the impedance of the culture medium but also of changes in the ionic layers at the measuring electrodes, which has advantages in case of high salt concentrations. These changes are expressed as percentage decreases of the initial values, M-value and E-value, respectively. Food samples were pre-enriched 14 to 16 h at 37°C in peptone water by addition of mannitol, which facilitated the detection of salmonellae on selective culture media. Following this, 0.1 mi of the preenrichment culture was transferred to 9.9 ml of Impedance-Splitting Salmonellae (ISS) medium which consisted of magnesium chloride (hydrated), malachite green oxalate, novobiocin, phosphate buffer, mannitol, peptone and yeast extract. Despite the high magnesium chloride concentration in this medium, salmonellae produced changes of the E-value up to 100%, while the changes in M-values were limited to a few percent. The impedance changes were automatically recorded during incubation in the measuring system for up to 22 h at 40°C, and the time required to exceed a threshold value of 15% (E reaction time) was evaluated. Comparative testing of the ISS method with standard cultural analysis of 250 unknown food samples showed high sensitivity and selectivity in detecting salmonellae. From all of the 122 Salmonella-positive samples, the largest number (119) was obtained by the ISS method, as compared to that obtained by conventional testing with the selenite-cystine (106), Rappaport Vassiliadis soya (95), Rappaport Vassiliadis (92) and tetrathionate brilliant green medium (64). Six samples were false positive by Enterobacter cloaceae. One strain each of Salmonella enteritidis PT8 and Salmonella panama were not recorded. The ISS method is very suitable as a screening test, all the more since a negative investigation result will be obtained within 38 h. In view of the practicability, this method is superior to the enzyme-immunological and molecular-biological procedures.

Publisher

International Association for Food Protection

Subject

Microbiology,Food Science

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3