Improving the Detection Accuracy and Time for Campylobacter jejuni and Campylobacter coli in Naturally Infected Live and Slaughtered Chicken Broilers Using a Real-Time Fluorescent Loop-Mediated Isothermal Amplification Approach

Author:

SABIKE ISLAM IBRAHIM12,YAMAZAKI WATARU13

Affiliation:

1. Department of Veterinary Sciences, Faculty of Agriculture (ORCID: http://orcid.org/0000-0002-7874-8014 [W.Y.]), University of Miyazaki, Miyazaki, Japan

2. Department of Food Control, Faculty of Veterinary Medicine, Benha University, Egypt

3. Center for Animal Disease Control, University of Miyazaki, Miyazaki, Japan

Abstract

ABSTRACT Rapid and accurate identification of Campylobacter-positive broiler flocks and carcasses expedites separation and control interventions before release into the food supply chain and directly facilitates a reduction in the prevalence of human campylobacteriosis. In this study, the diagnostic performance of fluorescent loop-mediated isothermal amplification (LAMP) assays for the direct detection of Campylobacter jejuni and Campylobacter coli in broiler cloacal and cecal samples were evaluated and compared with that of turbidimetric LAMP approaches investigated previously. The duplex fluorescent LAMP assay had significantly higher (P < 0.05) diagnostic sensitivity (93.1%, 54 of 58 samples) than did the turbidimetric LAMP assay (82.8%, 48 of 58 samples) for detecting C. jejuni and C. coli in broiler cloacal samples, whereas the singleplex fluorescent LAMP assay had equivalent diagnostic sensitivity. For cecal samples, the diagnostic sensitivity of the fluorescent LAMP assay (100%, 38 of 38 samples) was the same as that of the turbidimetric LAMP. Fluorescent LAMP significantly reduced (P < 0.05) the maximum detection time for Campylobacter-positive cloacal and cecal samples to 28 and 11 min, respectively, and reduced the influence of amplification inhibitors responsible for most false-negative results obtained for cloacal samples with the turbidimetric LAMP assay. The diagnostic accuracy of the fluorescent LAMP assay for the direct detection of C. jejuni and C. coli in cloacal and cecal samples was 97.7 and 100%, respectively. These findings indicate that fluorescent LAMP assays are robust, highly accurate, and field-applicable methods for the identification of C. jejuni and C. coli, which will allow more accurate monitoring of food safety at various stages of the food supply chain at farms and slaughter facilities.

Publisher

International Association for Food Protection

Subject

Microbiology,Food Science

Reference23 articles.

1. Broiler carcass contamination with Campylobacter from feces during defeathering;Berrang;J. Food Prot,2001

2. The European Union summary report on trends and sources of zoonoses, zoonotic agents and food-borne outbreaks in 2016;European Food Safety Authority and European Centre for Disease Prevention and Control;EFSA J,2017

3. Salmonella and Campylobacter in chicken meat;Food and Agriculture Organization of the United Nations and World Health Organization;Microbiological risk assessment series 19,2009

4. Food Safety Authority of Ireland. 2011. Report of the scientific committee of the Food Safety Authority of Ireland. Recommendations for a practical control programme for Campylobacter in the poultry production and slaughter chain. Food Safety Authority of Ireland, Dublin.

5. Rapid detection, characterization, and enumeration of foodborne pathogens;Hoorfar;APMIS Suppl,2011

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3