Evaluation of Modified Moore Swabs and Continuous Flow Centrifugation for Concentration of Salmonella and Escherichia coli O157:H7 from Large Volumes of Water

Author:

BISHA BLEDAR1,PEREZ-MENDEZ ALMA1,DANYLUK MICHELLE D.2,GOODRIDGE LAWRENCE D.1

Affiliation:

1. 1Center for Meat Safety and Quality, Food Safety Cluster, Department of Animal Sciences, Colorado State University, Fort Collins, Colorado 80523

2. 2Citrus Research and Education Center, Department of Food Science and Human Nutrition, Institute of Food and Agricultural Sciences, University of Florida, Lake Alfred, Florida 33850, USA

Abstract

Modified Moore swabs (MMS; consisting of a polyvinyl chloride cartridge filled with gauze) capture microorganisms within the packed gauze as water flows through the cartridge, while continuous flow centrifugation (CFC) uses centrifugation to sediment the microorganisms while water continuously flows in the system. This study evaluated and compared the efficacy of MMS and CFC for concentration and subsequent detection of Escherichia coli O157:H7 and Salmonella from large volumes of water (10 liters). Water samples were spiked at levels of 101,102,103, and 104 CFU/100 ml with three-strain cocktails of either E. coli O157:H7 or Salmonella serovars, which had been previously transformed with a plasmid to express resistance to ampicillin as well as green, red, or cyan fluorescent proteins. Plating was performed before and after concentration on tryptic soy agar supplemented with ampicillin in order to quantitate the concentration efficiencies of each method. The two lowest spiking levels were also enriched in low volumes of tryptic soy broth supplemented with ampicillin followed by testing via lateral flow devices. Significant (P < 0.05) concentrations of initial levels of E. coli O157:H7 in the range of 0.7 to 1.0 and 1.2 to 1.4 log were achieved within approximately 35 min of processing time via MMS and CFC, respectively. Similarly, significant (P < 0.05) concentrations were also achieved for Salmonella with 0.9 to 1.2 and 1.2 to 1.4 log concentration for MMS and CFC, respectively. There were no statistical differences (P > 0.05) between the two concentration methods in their ability to concentrate either of the two target bacteria. Significantly (P < 0.05) more spiked samples were detected by lateral flow devices following concentration and enrichment than for nonconcentrated, enriched samples. It is concluded that both MMS and CFC have potential to be used to enhance the sensitivity of downstream bacterial detection methods used to test irrigation water for the presence of foodborne pathogens.

Publisher

International Association for Food Protection

Subject

Microbiology,Food Science

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3