Author:
Gedik Engin,Kurt Hüseyin,Pala Murat,Alakour Abdulla,Kaya Metin
Abstract
The main purpose of this study is to investigate the thermal efficiency of a
Two-Phase Closed Thermosyphon (TPCT). For this purpose, initially, an
experimental study was performed, then to predict the other experimental
conditions ANN model which has used a wide range of thermal engineering
systems was developed. A vertical copper pipe charged with different working
fluids as pure water, ethanol, and ethylene glycol were used for TPCT. Impact
of the various parameter such as heating power input, inclination angle, cooling
water flow rate and working fluid type on the TPCT efficiency are examined. It
is found that the increase in the inclination angle increased the TPCT efficiency
while the increase in heating power input decreased efficiency. Regression
analysis was applied to examine the performance of ANN between estimated
and experimental data. The Mean Absolute Percentage Error (MAPE) was
found to be less than 1.3 % for the training set and 3.1% for the test data set.
The ANN predictions yield R2 in the range of 0.9998 for the training set and
0.9989 for the test data set. The obtained results from the experimental study
and ANN were found in good agreement, and it is also concluded that from the
study the ANN is a useful tool to estimate such thermal engineering problems.
Keywords:
Thermal efficiency
Heat pipe
Two-phase closed
thermosyphon
ANN
Cited by
1 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献