Development of a Reference Installation for Metrological Support of the Delta Value Measurements of the Ratio of Carbon and Oxygen Isotopes in Exhaled Air

Author:

Chubchenko I. K.1ORCID,Kolobova A. V.1ORCID,Larosh A. V.1,Afanasyev G. A.1

Affiliation:

1. D. I. Mendeleyev Institute for Metrology

Abstract

Breath tests in domestic and foreign medicine are recognized as an effective and safe way to identify pathogens in the gastrointestinal tract, in particular the Helicobacter Pylori bacteria. At the end of the 20th century, a urease breath test was introduced into clinical practice to diagnose diseases of the gastrointestinal tract; it was based on the use of urea labeled with a stable isotope 13C ( 13C-urease breath test). The essence was to measure the delta value of the ratio of carbon and oxygen isotopes in exhaled air.Over decades of clinical practice of using this test, a wealth of experience related to the diagnosis of diseases caused, including by the Helicobacter Pylori bacteria has been accumulated. A significant amount of knowledge has also been accumulated in terms of metrological support of the carbon and oxygen isotope delta in exhaled air.The article describes the procedure and results of developing a development of a measurement standard of carbon and oxygen isotope delta in exhaled air, implemented within the R&D a/c No. «Sistema-2020-М» at the D. I. Mendeleyev Institute for Metrology (VNIIM). The authors presented the theoretical study, test methodology, their sequence and results. The article also contains a report on the international comparisons CCQM-P204 “Isotope ratios of CO2 (δ13VPDB and δ18VPDB) in pure CO2” with the application of the measurement standard developed by VNIIM. The metrological characteristics of the measurement standard obtained during the comparisons correspond to the most accurate measurements of the ratio of carbon and oxygen isotopes, which guarantees the recognition of the measurement results at the international level. Considering the high demand for breath tests in medical practice and obvious prospects of this type of diagnostics, further research will be aimed at creating a State Primary Standard for the delta value unit of the ratio of isotopes of carbon, oxygen, hydrogen based on the created measurement standard and the development of certified reference materials of the ratio of isotopes of carbon, oxygen, hydrogen in liquid, solid, and gaseous media, including for the purpose of replacing foreign-made materials.

Publisher

Ural Research Institute of Metrology (UNIIM)

Reference15 articles.

1. Hennessy E. O. Serological markers of celiac disease and impaired motor evacuation function of the stomach in children and adolescents with type 1 diabetes mellitus. PhD (Eng.). sci. diss., Endocrinological Research Center of the Ministry of Health and Social Development of the Russian Federation. Available at (In Russ.): https://www.endocrincentr.ru/sites/default/files/specialists/science/dissertation/hennessy.pdf?ysclid=luqw9v9biw282464994 [Accessed 17 January 2024].

2. Elman A. R., Rapoport S. I. Stable isotope diagnostics in Russia: results and prospects. 13C-drugs, devices, methods. Klinicheskaya medicina. 2014;92(7):5–11. (In Russ.).

3. Zaikin V. G. Chromatography-mass spectrometry. Journal of Analytical Chemistry. 2011;66(11):1090–1094. (In Russ.).

4. Kolobova A. V., Chubchenko Ya. K., Afanasyev G. A. Development of a reference installation for metrological support for the diagnosis of diseases caused by Helicobacter Pylori infection based on the determination of carbon and oxygen isotopes in exhaled air. In: Collection of abstracts of the II International Scientific and Practical Conference of Young scientists and specialists «Za nami budushchee» and X International Competition «The best young metrologist КООМЕТ – 2023», 14–16 June 2023, Ekaterinburg, Russia. Federal Agency for Technical Regulation and Metrology et al: Saint-Petersburg: ООО «Izdatel’sko-poligraficheskaya kompaniya “Kosta”»; 2023. P. 236–238. (In Russ.).

5. Grishkanich A., Chubchenko Y., Elizarov V., Zhevlakov A., Konopelko L. SRS-sensor 13C/12C isotops measurements for detecting Helicobacter Pylori. In: Optical fibers and sensors for medical diagnostics and treatment applications XVIII. Vol. 10488. SPIE; 2018. P. 198–209. https://doi.org/10.1117/12.2295927