Hypothermic machine perfusion of a donor kidney using an experimental dextran-40-based preservation solution and orthotopic transplantation (experimental study)

Author:

Shestakova V. G.1,Bogdanov V. K.2,Pavlov R. D.1,Terekhov V. M.1,Timanovsky A. S.1,Zharikov A. A.2,Shibaev A. N.3,Grudinin N. V.2

Affiliation:

1. Tver State Medical University

2. Shumakov National Medical Research Center of Transplantology and Artificial Organs

3. Tver State Medical University; Vladimirsky Moscow Regional Research and Clinical Institute

Abstract

Objective: to evaluate the efficacy of hypothermic machine perfusion (HMP) of a donor kidney obtained from a non-heartbeating (NHB) donor, using an experimental dextran-40-based preservation solution, in subsequent orthotopic transplantation in a rabbit model.Materials and methods. Twenty grey giant rabbits weighing 2,500–3,100 g, divided into donors (n = 10) and recipients (n = 10), were used in the study. After obtaining kidney from an NHB donor, ex vivo HMP of the left donor kidney using a dextran-40-based preservation solution was performed and peripheral vascular resistance (PVR) parameters were measured. This was followed by bilateral nephrectomy and orthotopic transplantation. The follow-up period was 12 days. Creatinine levels, urea levels, and glomerular filtration rate (GFR) were measured during follow-up.Results. During ex vivo HMP of donor kidneys from NHBs, PVR dropped progressively from 1.90 ± 0.27 mmHg/mL/min to 0.72 ± 0.09 mmHg/mL/min at p < 0.001. In the early post-transplant period (during the first 2 days after implantation), creatinine and urea levels were moderately elevated compared to normal. Creatinine and urea levels were 91.07 ± 11.49 μmol/L at p < 0.011 and 9.09 ± 1.06 mmol/L at p < 0.009 on day 2, respectively, but by day 12, they reverted to physiologic values, which were 77.17 ± 10.19 μmol/L at p < 0.019 and 4.88 ± 0.54 mmol/L at p < 0.022, respectively. These findings were correlated with GFR values, which ranged from 26.29 to 26.74 mL/min/1.72 m2 in mean values over the course of a 12-day follow-up period.Conclusion. Ex vivo HMP using dextran-40-based preservation solution has a positive effect on the kidney at 30 minutes of warm ischemia following asystole and achieves satisfactory graft function over 12 days of follow-up.

Publisher

V.I. Shimakov Federal Research Center of Transplantology and Artificial Organs

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3