Percutaneous left ventricular assist device as a short-term mechanical circulatory support before heart transplantation in patients with high pre-transplant pulmonary hypertension (series of clinical cases)

Author:

Poptsov V. N.1,Slobodyanik V. V.1,Spirina E. A.1,Petukhov N. V.1,Solodovnikova A. K.1,Voronkov V. Yu.1,Dogonasheva A. A.1,Skokova A. A.1

Affiliation:

1. Shumakov National Medical Research Center of Transplantology and Artificial Organs

Abstract

Federation In certain categories of patients with end-stage heart failure (HF), short-term mechanical circulatory support (MSC) is successfully used as a mechanical «bridge» to heart transplantation (HTx). In predominantly left-ventricular (LV) dysfunction, the use of isolated coronary artery bypass, especially amidst high pulmonary hypertension (PH), seems to be a more physiological method of short-term MSC.Objective: to present the results of a series of clinical cases of the use of percutaneous left ventricular assist device (pLVAD) before HTx in potential recipients with predominantly LV dysfunction and concomitant high PH.Materials and methods. Three potential heart recipients with predominantly left-sided HF and high pre-transplant PH (pulmonary vascular resistance, PVR, 4.7–6.6 Wood units) who required MSC due to progression of hemodynamic disorders were included in the study. A standard venous extracorporeal membrane oxygenation (ECMO) cannula (26 F) was used for percutaneous left atrial-femoral artery (LA–FA) bypass. The cannula was passed from the transfemoral route through the interatrial septum into the left atrial cavity. A paracorporeal centrifugal pump provided blood injection through a standard arterial ECMO cannula (15 F).Results. pLVAD unloaded the left ventricle effectively (PCWP reduced from 27–32 to 15–20 mmHg), reduced pre-transplant PH (mean pulmonary artery pressure (mPAP) reduced from 45–53 to 28–33 mmHg) and improved systemic hemodynamics (cardiac index (CI) increased from 1.8–1.9 to 2.1–2.6 l/min/m2 and mean arterial pressure (mAP) from 56–59 to 70–75 mmHg). All these created the prerequisites for subsequent successful HTx. Against the background of pLVAD, transpulmonary pressure gradient (TPG) decreased from 15–25 to 13–15 mmHg, and PVR decreased from 4.7–6.6 to 2.7–3.4 Wood units. pLVAD flow rate was 2.9–3.8 L/min or 1.38–1.83 L/min/m2 at 4700–7100 rpm. pLVAD duration ranged from 4 (n = 1) to 7 (n = 2) days. All patients underwent successful HTx.Conclusion. pLVAD is a highly effective method of short-term MSC in potential recipients with predominantly LV dysfunction and concomitant high PH, leading to rapid regression of the dysfunction against the background of left ventricular unloading. This short-term MSC technique can be successfully realized using standard ECMO cannulas and centrifugal pumps of any modification, without requiring additional special equipment.

Publisher

V.I. Shimakov Federal Research Center of Transplantology and Artificial Organs

Subject

Transplantation,Immunology and Allergy

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3