Author:
Seth Ashok,Gupta Sajal,Pratap Singh Vivudh,Kumar Vijay, , , ,
Abstract
Final stent dimensions remain an important predictor of restenosis, target vessel revascularisation (TVR) and subacute stent thrombosis (ST), even in the drug-eluting stent (DES) era. Stent balloons are usually semi-compliant and thus even high-pressure inflation may not achieve uniform or optimal stent expansion. Post-dilatation with non-compliant (NC) balloons after stent deployment has been shown to enhance stent expansion and could reduce TVR and ST. Based on supporting evidence and in the absence of large prospective randomised outcome-based trials, post-dilatation with an NC balloon to achieve optimal stent expansion and maximal luminal area is a logical technical recommendation, particularly in complex lesion subsets.
Subject
Cardiology and Cardiovascular Medicine
Cited by
18 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献