The role of anterior segment optical coherence tomography in the detection of predictors of ophthalmic hypertension associated with anti-VEGF injections

Author:

Andreeva Y. S.1ORCID,Alharki L.1ORCID,Shelankova A. V.1ORCID,Budzinskaya M. V.1ORCID

Affiliation:

1. Krasnov Research Institute of Eye Diseases

Abstract

PURPOSE. To identify the predictors of increased intraocular pressure (IOP) after intravitreal injection (IVI) of an antiVEGF drug using anterior segment optical coherence tomography (AS-OCT), and to study changes in the iris-lens diaphragm produced by multiple injections in the treatment of neovascular form of age-related macular degeneration (nAMD).METHODS. IOP was measured with an ICare Pro tonometer before IVI, 1 minute after IVI, 30 minutes, 60 minutes and 180 minutes later. Anterior chamber depth (ACD), anterior chamber angle (ACA), and lens thickness were assessed using Revo NX tomograph (Optopol, Poland). The study was carried out before IVI, one month after the first IVI, one month after the third IVI, one year after the start of treatment. Axial length was measured once before IVI.RESULTS. An inverse correlation was found between axial length and an increase in IOP 1 min after IVI (r=0.65, p<0.001). According to AS-OCT data, one year after the start of treatment there was a significant decrease in ACD compared to the data before treatment (p><0.001), as well as a decrease in all parameters of ACA (p><0.05). Shorter axial length (R2 =0.45, p><0.05), shorter ACD (R2 =0.44, p><0.05), smaller ACA on the nasal (R2 =0.37, p><0.05) and temporal (R2 =0.39, p><0.05) sides in patients with their own lens led to a greater rise in IOP 1 min after IVI.CONCLUSION. Predictors of a sharp increase in IOP after IVI of an anti-VEGF drug in patients with nAMD that can be detected with AS-OCT are shorter ACD and smaller ACA. The following prognostic model was determined — with a 1-mm decrease in the axial length, an increase in IOP by 2.3 mm Hg should be expected, a decrease in ACA from the temporal side by 1° leads to an increase in IOP of 0.28 mm Hg>

Publisher

Research Institute of Eye Diseases

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3