Abstract
The determination of internal building air temperature has an impact on the design and performance of a building in measuring thermal comfort and heating and cooling loads. There is software to assist with measuring internal building air temperature such as Autodesk CFD simulation. However, the use of Autodesk CFD simulation for the analysis appears to have an issue with simulations extending over a long term (i.e. months or years) as the internal air temperature in a building keeps rising with time. This paper addresses the challenges encountered using CFD simulation in the modelling of a building for long term performance. A new method to overcome the issue of the progressive rising of internal air temperature using two external air boundaries, one for the external volume (sky boundary) and the other surrounding the building, is suggested in the paper.
Subject
General Environmental Science,Geography, Planning and Development,Civil and Structural Engineering,Building and Construction,Architecture,Environmental Engineering,Management, Monitoring, Policy and Law,Nature and Landscape Conservation,Public Health, Environmental and Occupational Health