Impact of Total Corneal Astigmatism Estimated With the Abulafia-Koch Formula Versus Measured With a SS-OCT Biometer on the Refractive Outcomes of a Toric Intraocular Lens in Cataract Surgery

Author:

Rémignon Charles-Henry,Levron Antoine,Agard Emilie,Douma Ikrame,El-Chehab Hussam,Brunet Olivier,Sejournet Lucas,Billant Jeremy,Dot Corinne

Abstract

Purpose: To compare the impact of total corneal astigmatism (TCA) estimated with the Abulafia-Koch formula (TCA ABU ) versus measured by Total Keratometry (TK), swept-source optical coherence tomography (OCT) coupled with telecentric keratometry (TCA TK ) on the refractive outcomes after cataract surgery with toric intraocular lens (IOL) implantation. Methods: Two hundred one eyes of 146 patients who underwent cataract surgery with toric IOL implantation (XY1AT; HOYA Corporation) were included in this single-center, retrospective study. For each eye, TCA ABU (estimated from the anterior keratometry values measured with the IOLMaster 700 [Carl Zeiss Meditec AG]) and TCA TK (measured using TK IOLMaster 700) were entered into the HOYA Toric Calculator. Patients were operated on based on TCA ABU . For each eye, centroid and mean absolute error in predicted residual astigmatism (EPA) were calculated according to TCA used (TCA ABU or TCA TK ). The cylinder power and the axis of the posterior chamber IOL were compared. Results: The mean uncorrected distance visual acuity was 0.07 ± 0.12 logMAR, the mean spherical equivalent was 0.11 ± 0.40 D, and mean residual astigmatism was 0.35 ± 0.36 D. Mean centroid EPA was 0.28 D at 132° with TCA ABU and 0.35 D at 148° with TCA TK ( P (x) < .001; P (y) < .01). Mean absolute EPA was 0.46 ± 0.32 D with TCA ABU and 0.50 ± 0.37 D with TCA TK ( P < .01). In the with-the-rule astigmatism subgroup, a deviation from the target of less than 0.50 D was achieved in 68% of eyes with TCA ABU versus 50% of eyes with TCA TK . The proposed posterior chamber IOL was different depending on the calculation methods used in 86% of cases. Conclusions: Both calculation methods showed excellent results. However, the predictability error was significantly reduced when TCA ABU was used compared to TCA TK measured with the IOLMaster 700 in the whole cohort. Finally, TCA was overestimated by TK in the with-the-rule astigmatism subgroup. [ J Refract Surg. 2023;39(3):171–179.]

Publisher

SLACK, Inc.

Subject

Ophthalmology,Surgery

Cited by 5 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司