Three-Month Clinical Outcomes to Correct Myopia or Myopic Astigmatism Using a Femtosecond Laser for Lenticule Creation With Automated Centration and Cyclotorsion Compensation

Author:

Yoon Hyosung,Magnago Thomas,Yeom Donjg-Ju

Abstract

Purpose: To individually evaluate the clinical outcomes for right and left eyes in the first 3 months after laser-assisted lenticule extraction for myopia and myopic astigmatism with the use of the new ATOS femtosecond laser system (Smart-Sight; SCHWIND eye-tech-solutions). Methods: A total of 331 eyes from 168 patients (166 right eyes and 165 left eyes) consecutively treated with SmartSight lenticule extraction were retrospective analyzed after a 3-month follow-up period. Patients' mean age was 26 ± 6 years (range: 18 to 47 years) and mean preoperative spherical equivalent (SEQ) was −5.07 ± 1.92 diopters [D] (range: −1.50 to −11.25 D) with a mean astigmatism of −1.04 ± 0.85 D (range: 0.00 to −4.00 D). At 3 months of follow-up, visual acuity, SEQ and cylinder, safety index, efficacy index, corneal higher order aberrations, and intraocular pressure (IOP) were analyzed. Furthermore, refractive and visual outcomes were also analyzed for the right and left eyes individually. All lenticule extraction treatments were performed with the SmartSight treatment method of the SCHWIND ATOS femtosecond laser. Results: At 3 months after surgery, mean SEQ was −0.12 ± 0.19 D and 98% of eyes were within ±0.50 D of the SEQ. All eyes were within ±1.00 D of the SEQ. Astigmatism of 0.50 D or less was achieved in 99% of eyes. The change in Snellen lines (difference between preoperative corrected distance visual acuity and postoperative uncorrected distance visual acuity) showed a gain of one or more lines in 13% and in 85% of the eyes the same was achieved. There was a loss of one or more lines at 3 months of follow-up in 1.6%. The safety index was 1.03 and efficacy index was 1.02. No significant difference between the right and left eyes was found. Conclusions: The 3-month follow-up data show that SmartSight treatment for correction of myopia and myopic astigmatism with the SCHWIND ATOS is a safe, efficient, and accurate procedure. It provided excellent results in terms of visual recovery, predictability, and higher order aberrations. [ J Refract Surg . 2024;40(1):e30–e41.]

Publisher

SLACK, Inc.

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3