Repeatability and Agreement of a New Scheimpflug Device and a Hartmann-Shack Aberrometer With a Ray-Tracing Aberrometer in Normal, Keratoconus, and CXL Groups

Author:

Kundu Gairik,Shetty Rohit,Ranade Reshma,Trivedi Divya,Lalgudi Vaitheeswaran Ganesan,Nuijts Rudy M.M.A.,Annavajjhala Sriram,Khamar Pooja

Abstract

PURPOSE: To assess repeatability and agreement of a Scheimpflug topographer and a Hartmann-Shack aberrometer with a ray-tracing aberrometer in normal, keratoconus, and corneal cross-linking (CXL) groups. METHODS: In this cross-sectional, observational study, normal, keratoconus, and CXL groups with 125 eyes in each of the three groups were included. All eyes underwent three sets of measurements, at a single visit, using the Pentacam AXL Wave (Oculus Optikgeräte GmbH) and iTrace (Tracey Technologies). Keratometry, pachymetry, objective refraction, and total ocular aberrations including root mean square (RMS) lower order aberrations (LOAs), RMS higher order aberrations (HOAs), RMS coma, and spherical aberrations (SA) were analyzed. Objective assessment of haze after CXL was done using the Pentacam AXL Wave. Repeatability was assessed using within-subject standard deviation (Sw), test–retest variability, within-subject coefficient of variation (COV), and intraclass correlation coefficient (ICC). Bland-Altman analysis assessed 95% limits of agreement and correlation coefficient ( r ) determined the strength of the relationship between measurements. RESULTS: The Pentacam AXL Wave had Sw for keratometry of 0.12 in the normal group and 0.15 in the keratoconus group and lower (poorer) Sw of 0.17 in the CXL group. For pachymetry, Sw was 9.18, 9.53, and 10.11 in the normal, keratoconus, and CXL groups, respectively. Total aberrations had ICCs ranging from 0.88 for RMS HOAs to 0.95 for SA in the normal group, 0.86 for RMS HOAs to 0.92 for SA in the keratoconus group, and 0.72 for RMS HOAs to 0.82 for SA (poorer) in the CXL group. In the normal group, mean differences between the two devices were nonsignificant for all parameters except SA (0.011 ± 0.038 μm, P < .01; limits of agreement = −0.09 to 0.07; r = 0.87). In the keratoconus group, mean differences were significant in all aberrations except RMS LOAs (−0.27 ± 0.85 μm, P = .10; limits of agreement = −3.3 to 3.8; r = 0.92). In the CXL group, all parameters varied significantly ( P < .006). CONCLUSIONS: The Pentacam AXL Wave showed comparable repeatability in the normal and keratoconus groups, but was poorer in the CXL group, more so with increasing corneal haze. Both devices can be used interchangeably in normal eyes, except for SA, but not in eyes with keratoconus or CXL for aberration measurements. [ J Refract Surg . 2022;38(3):201–208.]

Publisher

SLACK, Inc.

Subject

Ophthalmology,Surgery

Cited by 4 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3