Is Astigmatism Correction Necessary for Patients With Cataract Who Have Corneal Astigmatism of Less Than 0.75 D?

Author:

Xie Xiaohang,Zhang Jiaqing,Han Xiaotong,Chen Xiaoyun,Qiu Xiaozhang,Huang Ruoxuan,Huang Yiguo,Ye Jinfeng,Wen Ling,Tan Xuhua,Luo Lixia,Liu Yizhi

Abstract

Purpose: To investigate the proportion of patients with predicted refractive astigmatism (PRA) of 0.75 diopters (D) or greater and associated risk factors among cataract surgery candidates with low corneal astigmatism. Methods: A retrospective cross-sectional study was conducted in Zhongshan Ophthalmic Center, Guangzhou, China. Patients with cataract who had preoperative simulated keratometric astigmatism of less than 0.75 D were recruited. The PRA was calculated by Barrett toric calculator using posterior corneal astigmatism (PCA) measured by the IOLMaster 700 (Carl Zeiss Meditec AG) and corneal surgically induced astigmatism (SIA). Two corneal incision locations (temporal [0°/180°], 135° incision) and varying magnitudes (0.10 to 0.60 D) were considered for SIA. Multiple logistic regression analysis was used to explore risk factors associated with PRA of 0.75 D or greater and build predictive model. Sensitivity analysis was performed using PRA threshold of 0.50 D. Results: A total of 1,750 eyes from 1,750 patients were included (mean age: 60.14 ± 13.24 years, 42.91% male, 1,010 right eyes and 740 left eyes). The 135° incision (odds ratio [OR]: 17.86) and against-the-rule (ATR) astigmatism (OR: 37.55) are the major risk factors for PRA of 0.75 D or greater. Higher simulated keratometric astigmatism (OR: 2.03), larger PCA (OR: 1.64), and surgically induced astigmatism (OR: 1.29) also significantly increased the risk of PRA of 0.75 D or greater. Nomogram model were constructed with an area under curve of 0.90. Conclusions: For patients with corneal astigmatism of less than 0.75 D, temporal incision and measured PCA is preferred. Those patients with ATR astigmatism should be considered for astigmatism correction when using a 135° incision. [ J Refract Surg . 2023;39(12):850–855.]

Publisher

SLACK, Inc.

Subject

Ophthalmology,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3