Clinical Retinal Image Quality of a Non-diffractive Wavefront-Shaping Extended Depth of Focus (Vivity) Intraocular Lens

Author:

Al-Amri Saad Abdulrahman J.,Alió Jorge L.,Milán-Castillo Roberto,D'Oria Francesco,Martinez-Abad Antonio,Yebana Pilar,Subirana Nuria,Al-Harbi Ziyad,Plaza-Puche Ana B.,Alió del Barrio Jorge L.

Abstract

Purpose: To evaluate clinical retinal optical image quality following implantation of an extended depth of focus intraocular lens (EDOF IOL) (Vivity; Alcon Laboratories, Inc), and to compare it with a monofocal and a trifocal IOL. Methods: This prospective, comparative, case-control study included 88 eyes implanted with: (1) 19 monofocal IOLs (AcrySof SA60AT; Alcon Laboratories, Inc); (2) 38 EDOF IOLs (AcrySof IQ Vivity); and (3) 31 trifocal IOLs (AT LISA tri 839MP; Carl Zeiss Meditec AG). Total root mean square, ocular lower (LOA) and higher (HOA) order aberrations, point spread function (PSF) Strehl ratio (PSF with LOA), and PSF Strehl ratio excluding LOA (PSF without LOA) were analyzed using a Pyramidal WaveFront-based sensor aberrometer Osiris (Costruzione Strumenti Oftalmici) at two different pupil sizes (3 and 4 mm). Results: The trifocal IOL showed the highest PSF without LOA at both pupil sizes (0.52 ± 0.12 and 0.31 ± 0.07, respectively), followed by the AcrySof SA60AT (0.39 ± 0.10 and 0.27 ± 0.07) and AcrySof IQ Vivity (0.34 ± 0.11 and 0.24 ± 0.09) ( P < .001). The AcrySof IQ Vivity and monofocal IOLs were comparable ( P > .05). Despite the comparable postoperative low spherical equivalent among the IOL groups, the AT LISA tri 839MP retinal image quality (PSF with LOA) was the most severely affected by such residual refractive errors (dropped to 0.26 ± 0.06 at 3 mm; P < .001) compared to the monofocal AcrySof SA60AT (0.24 ± 0.07 at 3 mm) and EDOF Acrysof IQ Vivity (0.23 ± 0.06 at 3 mm) groups. The PSF with LOA was comparable ( P > .05) among the three groups at both the 3-and 4-mm pupil size. Conclusions: Although trifocal IOLs provided significantly better retinal image quality if influence of LOA is excluded, they also demonstrated to be the most sensitive to residual refractive errors. Both the EDOF Acrysof IQ Vivity and mono-focal AcrySof SA60AT IOLs showed a comparable retinal image quality, and they are also comparable with trifocal IOLs when considering the clinically real PSF (PSF with LOA). [ J Refract Surg . 2023;39(2):103–110.]

Publisher

SLACK, Inc.

Subject

Ophthalmology,Surgery

Reference30 articles.

1. Multifocal and Extended Depth-of-Focus Intraocular Lenses in 2020

2. Bala C, Lemp-Hull JM. Multi-country clinical outcomes of a new non-diffractive extended vision intraocular lens. Presented at the American Society of Cataract and Refractive Surgery Annual Meeting; May 16–17, 2020.

3. Extended depth of focus intraocular lenses for presbyopia

4. Extended Depth-of-Field Intraocular Lenses: An Update

5. Clinical Outcomes and Quality of Vision Associated with Bilateral Implantation of a Wavefront Shaping Presbyopia Correcting Intraocular Lens

Cited by 2 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3