Refractive Outcomes of Cataract Surgery in Patients With Intrastromal Femtosecond Laser Treatment of Presbyopia (INTRACOR)

Author:

Naujokaitis Tadas,Hallak Mustafa K.,Blöck Louise,Khoramnia Ramin,Auffarth Gerd U.

Abstract

Purpose: To evaluate the outcomes of cataract surgery with intraocular lens (IOL) implantation in patients who underwent intrastromal femtosecond laser treatment of presbyopia (INTRACOR). Methods: This was an interventional case series of 8 patients (10 eyes) who presented for cataract surgery 6.1 ± 3.2 years (mean ± standard deviation [SD]) after INTRACOR (Technolas Perfect Vision GmbH) treatment. A monofocal IOL was implanted in 9 eyes (7 patients) and a small-aperture IOL was implanted in 1 eye. The IOL power was calculated without adjustments using biometry obtained after the INTRACOR treatment. For additional calculations, keratometry obtained before the INTRACOR treatment was used. Postoperative examinations included visual acuity testing, manifest refraction, defocus curve, ocular biometry, corneal tomography, aberrometry, anterior segment optical coherence tomography, and slit-lamp examination. Results: After the cataract surgery, the mean ± SD uncorrected distance visual acuity was 0.37 ± 0.17 logMAR, the corrected distance visual acuity was 0.10 ± 0.10 logMAR, and the manifest refraction spherical equivalent, adjusted to infinity, was +0.39 ± 0.63 diopters (D). Intermediate and near visual acuity, both uncorrected and distance-corrected, and distance-corrected defocus curves varied considerably among patients. Using biometry performed after INTRACOR, the traditional IOL power calculation formulas produced hyperopic outcomes, with the mean ± SD prediction error ranging from +0.72 ± 0.34 to +0.96 ± 0.41 D. Although the mean ± SD prediction error decreased (range: −0.34 ± 0.56 to −0.15 ± 0.53 D) when using keratometry obtained before INTRACOR, the accuracy remained low due to high variability. Conclusions: In patients with cataract who had previous INTRACOR treatment, IOL power calculation could be inaccurate, with a tendency toward hyperopic outcomes. These results require confirmation in more extensive studies. [ J Refract Surg . 2023;39(10):676–682.]

Publisher

SLACK, Inc.

Subject

Ophthalmology,Surgery

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3