Camellin-Calossi Formula for Intraocular Lens Power Calculation in Patients With Previous Myopic Laser Vision Correction

Author:

Zollet Piero,Romeo Maria Angela,Tripepi Domenico,Vinciguerra Paolo,Vinciguerra Riccardo

Abstract

Purpose: To assess the performance of the Camellin-Calossi formula in eyes with prior myopic laser vision correction. Methods: This was a retrospective case series. Patients included had a history of uncomplicated myopic laser vision correction and cataract surgery. The primary outcome measures were cumulative distribution of absolute refractive prediction error, absolute refractive prediction error, and refractive prediction error. These parameters were estimated post-hoc using the Camellin-Calossi, Shammas, Haigis-L, Barrett True-K with or without history, Masket, and Modified Masket formulas and their averages starting from biometric data, clinical records, postoperative refraction, and intraocular lens power implanted. Results: Seventy-seven eyes from 77 patients were included. The Camellin-Calossi, Shammas, Haigis-L, Barrett True-K No History, Masket, Modified Masket, and Barrett True-K formulas showed a median absolute refractive error (interquartile range) of 0.25 (0.53), 0.51 (0.56), 0.44 (0.65), 0.45 (0.59), 0.40 (0.61), 0.60 (0.70), and 0.55 (0.76), respectively. The proportion of eyes with an absolute refractive error of ±0.25, 0.50, 0.75, 1.00, 1.50, and 2.00 diopters (D) for the Camellin-Calossi formula was 54.5%, 72.7%, 85.7%, 92.2%, 98.7%, and 100%, respectively. The cumulative distribution of the Camellin-Calossi formula showed the best qualitative performances when compared to the others. A statistically significant difference was identified with all of the others except the Haigis-L using a threshold of 0.25, with the Shammas, Modified Masket, and Barrett True-K at a threshold of 0.50 D and the Barrett True-K and Modified Masket at a threshold of 1.00 D. Conclusions: The Camellin-Calossi formula is a valid option for intraocular lens power calculation in eyes with prior myopic laser vision correction. [ J Refract Surg . 2024;40(3):e156–e163.]

Publisher

SLACK, Inc.

Cited by 1 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3