Non-invasive intracranial pressure estimation using ultrasonographic measurement of area of optic nerve subarachnoid space

Author:

Zhang YueORCID,Cao Kai,Pang Ruiqi,Wang Ning,Qu Xin,Kang Jun,Wang NingliORCID,Liu Hanruo

Abstract

ObjectiveTo verify whether the area of the ONSAS (ONSASA) obtained by transorbital ultrasonography can be used to accurately evaluate the intracranial pressure (ICP).MethodsThe recorded indexes included the optic nerve diameter, the optic nerve sheath diameter (ONSD), the width of both sides of the ONSAS (ONSASW) at 3 mm from the optic nerve head and the entire ONSASA outlined between 3 and 7 mm. After exploring and comparing five models to describe the relationship between body mass index (BMI), mean arterial blood pressure (MABP), ONSASA and ICP, the best model was determined.ResultsIn all, 90 patients with neurological diseases undergoing continuous invasive ICP monitoring were included in the study. In the training group, the correlation coefficient for the association between the ICP and ONSASA (Pearson’s correlation r=0.953) was higher than that for the association of the ICP with the ONSD (r=0.672; p<0.0001) and ONSASW at 3 mm behind the globe (r=0.691; p<0.0001). In the training group, the weighting function for prediction of the ICP was as follows: non-invasive ICP=2.050×ONSASA−0.051×BMI +0.036*MABP−5.837. With 20 mm Hg as the cut-off point for a high or low ICP, the sensitivity and specificity of ONSASA predicting ICP was 1.00 and 0.92. Receiver operator curve analysis revealed that the calculated cut-off value for predicting elevated ICP was 19.96 (area under curve= 0.960, 95% CI 0.865 to 1.00).ConclusionMeasurement of the ONSASA using ultrasonography can serve as a practical method for rapid and non-invasive quantification for evaluating ICP through an accurate mathematical formula with the BMI and MABP considered as contributing parameters.Trial registration numberThe study was registered in the Chinese Clinical Trial Registry (Study no ChiCTR2100045274).

Funder

Beijing Nova Program

Publisher

BMJ

Subject

Cellular and Molecular Neuroscience,Sensory Systems,Ophthalmology

Cited by 4 articles. 订阅此论文施引文献 订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献

同舟云学术

1.学者识别学者识别

2.学术分析学术分析

3.人才评估人才评估

"同舟云学术"是以全球学者为主线,采集、加工和组织学术论文而形成的新型学术文献查询和分析系统,可以对全球学者进行文献检索和人才价值评估。用户可以通过关注某些学科领域的顶尖人物而持续追踪该领域的学科进展和研究前沿。经过近期的数据扩容,当前同舟云学术共收录了国内外主流学术期刊6万余种,收集的期刊论文及会议论文总量共计约1.5亿篇,并以每天添加12000余篇中外论文的速度递增。我们也可以为用户提供个性化、定制化的学者数据。欢迎来电咨询!咨询电话:010-8811{复制后删除}0370

www.globalauthorid.com

TOP

Copyright © 2019-2024 北京同舟云网络信息技术有限公司
京公网安备11010802033243号  京ICP备18003416号-3