Author:
Draper Jane,Subbiah Sheila,Bailey Rikki,Chambers John B
Abstract
ObjectivesWe aimed to determine if auscultation or a point-of-care scan could reduce the need for standard echocardiography (transthoracic echocardiogram (TTE)) in community patients with asymptomatic murmurs.MethodsRequests from general practitioners were directed to a new murmur clinic. Auscultation and a point-of-care scan were performed by a cardiologist between 1 October 2013 and 31 December 2014 and by a scientist between 21 July 2015 and 9 May 2017.ResultsIn the first phase (cardiologist), there were 75 patients, mean age 54 (56 women), and in the second phase there were 100 patients, mean age 60 (76 women). In the total population of 175, abnormalities were shown on TTE in 52 (30%), on point-of-care scan in 52 (30%) and predicted on auscultation in 45 (26%) (p=0.125; 95% CI −0.02 to 0.29). The sensitivity of auscultation was not significantly different for the cardiologist (91%) as for the scientist (83%) (p=0.18; 95% CI −0.22 to 0.175) and the specificity was 100% for both. Accuracy was 97% for the cardiologist and 95% for the scientist. For the point-of-care scan, the sensitivity, specificity, positive and negative predictive values and accuracy were 100% for both cardiologist and scientist.ConclusionMost patients in a specialist murmur clinic had normal auscultation and point-of-care scans and no additional valve disease was detected by standard echocardiography. This suggests that a murmur clinic is a valid model for reducing demand on hospital echocardiography services.
Subject
Cardiology and Cardiovascular Medicine
Cited by
28 articles.
订阅此论文施引文献
订阅此论文施引文献,注册后可以免费订阅5篇论文的施引文献,订阅后可以查看论文全部施引文献