Author:
Sribnick Eric A,Wenger Nicole,Nicol Kathleen,Tobias Joseph D
Abstract
Viscoelastic monitoring (VEM) tools, such as rotational thrombelastometry, have been used extensively to measure coagulopathy in adults but have received less attention in paediatric care. The presented case involves a 5-year-old boy who was brought to the emergency department after a motor vehicle collision with a Glasgow Coma Scale score of 6T and extensive injuries, including a subdural hematoma. VEM was used to monitor the patient’s coagulopathy and to inform treatment measures by allowing real-time visualisation of the patient’s coagulation status. VEM was additionally used to direct blood product replacement in preparation for neurosurgical intervention, and 4-factor prothrombin complex concentrate (PCC) was used to help reverse the coagulopathy. The patient underwent successful hemicraniectomy after improvement of his coagulopathy. In paediatrics, VEM and PCC are increasingly being used for post-trauma coagulopathy, and this case highlights their potential promise and the need for further research.